FSP Custos 9X+ 1K uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 9 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 1 kVA
- Output power: 900 W
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
An intelligent online UPS with Rack and Tower design for commercial devices, enterprise server and high-end equipment.
User friendly LCD Display with graphic design. Quickly understand unit and power condition with visual indicators.
Emergency power off (EPO)
Uninterruptible power systems can be remotely powered off in the event of a fire or other emergency.
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 900 W
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
- Display typeType of display (screen) e.g. LCD.
- LCD
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
Show all 46 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 900 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 55 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 300 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40 - 70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 100 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 47/63 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- -1 - 1%
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 87%
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 85%
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 94%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 5:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm, Overload alarm
Other features
- Compatible operating systemsList of desktop operating systems tested as compatible with this product.
- Windows 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10; Linux; Unix; MAC
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 438 mm
- DepthThe distance from the front to the back of something.
- 410 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 88 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 12.9 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 4 ms
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 4 h
- Charging currentThe amount of electrical current supplied during the charging process, measured in amperes (e.g., 2/6/12).
- 1 A
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 2
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C20 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 9 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 50 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

FSP Champ Tower 10KL uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W

FSP Custos 9X + 3K uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 9 AC outlet(s)

FSP Champ Rack 6KL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W

FSP Custos 9X + 2K uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1800 W 9 AC outlet(s)

FSP Champ Tower 6KL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W

FSP iFP 600 uninterruptible power supply (UPS) Line-Interactive 0.6 kVA
360 W 2 AC outlet(s)