FSP Champ Rack 6KL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 5400 W
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 6 kVA
- Output power: 5400 W
- Compliance certificates: CE
All 40 specificationsProduct page at energy.fsp-europe.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
FSP Champ Rack Serie is the high density version of double-conversion online UPS with a output power factor 0.9. It’s designed in small cabinet with microprocessor controller. It also has USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relate contact cards.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 5400 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Input power cable, USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 40 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 5400 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 110 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 300 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 46/64 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 208 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 46/64 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 1%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Total Harmonic Distortion (THD) (linear load)The percentage of harmonic distortion present in the output waveform when powered by a linear load, measured in %.
- 3%
- Total Harmonic Distortion (THD) (non-linear load)The percentage of harmonic distortion present in the output waveform when the device is powering a non-linear load, measured in %.
- 5%
Packaging content
- Packaging contentA list of all items and documentation included in the box (e.g. Quick Start Guide).
- UPS, user manual, software CD, USB cable, cable for battery pack
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Input power cable, USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 530 mm
- DepthThe distance from the front to the back of something.
- 438 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 88 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 15 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 20
Ports & interfaces
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.9
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 50 dB
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 85078000
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

FSP Champ Rack 10KL uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W

FSP Champ Tower 6KL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W

FSP Champ Tower 10KL uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
9000 W

FSP Clippers RT 1K uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
1000 W

FSP Custos 9X+ 1K uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
900 W 9 AC outlet(s)

FSP Clippers RT 3K uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
3000 W