Eaton HotSwap MBP, HW power distribution unit (PDU) 1U Black
- Operating temperature (T-T): 0 - 45 °C
- Nominal input voltage: 220-250 V
- Maximum current: 16 A
- AC outlet types: Terminal
- PDU types: Basic
- Rack capacity: 1U
All 11 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
High availability for all UPSs up to 3 kVA.
- HotSwap MBP provides a maintenance bypass for all UPSs up to 3 kVA: UPSs can be hot swapped or upgraded without interrupting the power supply
- HotSwap MBP has an IEC16A input connector with retaining clip for compatibility with any UPS now and in the future from Eaton or any other supplier
- There is a range of HotSwap MBP units with different output connectors: French, British and IEC sockets - terminal blocks on the HW (Hard-Wired) version
- HotSwap MBP units can be installed as required; at the back, side, top of the UPSs, or rack-mounted (horizontally (1.5U) or vertically)
The Eaton HotSwap MBP series is made of versatile, flexible 2U PDUs designed to add high availability to UPSs up to 3,000 VA. Any UPS connected to a HotSwap MBP can be replaced for maintenance or upgrade purposes without interrupting the power supply to the protected devices. As a unique feature, they can be screwed at the back a Pulsar UPS, either front-facing or rear-facing, on the left or right hand side, for maximum versatility. They offers multiple mounting options for rack enclosures, wall mounting or connection at the rear of a UPS, whatever its brand.
Features and Benefits
- Adds high availability to UPSs up to 3,000 VA
- Can be rackmounted, wallmounted or connected at the rear of an Eaton UPS in 3 different ways
- 2U versatile power distribution unit
- Easy plug-in connectivity
- Universal solution
Specifications
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 483 mm
- DepthThe distance from the front to the back of something.
- 120 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 52 mm
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-250 V
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Terminal
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 1U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton HotSwap MBP, 6x IEC power distribution unit (PDU) 6 AC outlet(s) 1U Black

Eaton HotSwap MBP, 4x FR power distribution unit (PDU) 4 AC outlet(s) 1U Black

Eaton APS3-058-0 power distribution unit (PDU) 3U

Eaton HotSwap MBP, 4x DIN power distribution unit (PDU) 4 AC outlet(s) 1U Black

Eaton APS3-058-8 power distribution unit (PDU) 3U