Eaton FlexPDU, 8x FR power distribution unit (PDU) 8 AC outlet(s) 1U Black
- AC outlets quantity: 8 AC outlet(s)
- Operating temperature (T-T): 0 - 45 °C
- Nominal input voltage: 220-250 V
- Maximum current: 16 A
- Power plug: C20 coupler
- AC outlet types: Type E
All 12 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Having the right connectors just where you need them
- FlexPDUs (Power Distribution Units) are flexible mounting multiway socket blocks for easy connection of multiple loads or either free-standing or rack-mounted UPSs.
- FlexPDUs have a large number of sockets (8 French sockets, 6 BS sockets or 12 IEC 10A sockets) which fit into a very compact unit (1U - 19").
- FlexPDUs are easy to implement into any type of installation: they can be rack mounted horizontally (1U) or vertically or directly onto all MGE RT format (rack/tower) UPSs.
These basic rack PDUs are versatile, flexible power strips intended to provide more connection options when using rackmount UPSs. The FlexPDU series is compatible with any UPS below 3 kVA and is the perfect power distribution option for the Evolution, EX and M series while the high voltage PDUs are compatible with the EX RT UPS series. These PDUs offer multiple mounting options for rack enclosures, wall mounting or connection at the rear of the UPS.
Features and Benefits
- Extend the number of devices that can be connected to a single UPS
- Can be rackmounted, wallmounted or connected at the rear of a Eaton UPS in 3 different ways
- 1U versatile power distribution unit
- Easy plug-in connectivity
- Universal solution
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C20 coupler
- AC outlet typesThe type of outlet for AC electricity.
- Type E
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 483 mm
- DepthThe distance from the front to the back of something.
- 80 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 220-250 V
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 1U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton HotSwap MBP, 4x DIN power distribution unit (PDU) 4 AC outlet(s) 1U Black

Eaton FlexPDU, 8x DIN power distribution unit (PDU) 8 AC outlet(s) 1U Black

Eaton HotSwap MBP, 4x FR power distribution unit (PDU) 4 AC outlet(s) 1U Black

Eaton PoE Midspan 24-ports power distribution unit (PDU)

Eaton HotSwap MBP, HW power distribution unit (PDU) 1U Black