CyberPower OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 4 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 1 kVA
- Output power: 900 W
- Nominal input voltage: 120 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 900 W
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 120 V
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- NOM
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Phone (RJ-11), USB cable
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
Show all 67 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Battery replacement
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 900 W
- Cable lengthHow long the cable is.
- 1.8 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 80 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 150 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 100 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 127 V
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 440 J
- Transfer time (Line Mode to Battery Mode)The time required for the device to switch from mains power to battery power during a power failure, measured in ms.
- 0 ms
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 95%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.98
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Overload capacity (1 minute)The maximum percentage of the rated load that the unit can sustain for a duration of one minute without failure, measured in %.
- 120%
- Overload capacity (10 seconds)The maximum percentage of the rated load that the unit can sustain for a duration of 10 seconds without failing, measured in %.
- 120%
- Overload capacity - line mode (1 minute)The maximum percentage of the rated load that the device can sustain for one minute while operating in line mode, measured in %.
- 120%
- Total Harmonic Distortion (THD) (linear load)The percentage of harmonic distortion present in the output waveform when powered by a linear load, measured in %.
- 3%
- Total Harmonic Distortion (THD) (non-linear load)The percentage of harmonic distortion present in the output waveform when the device is powering a non-linear load, measured in %.
- 5%
- EMI/RFI noise filteringThe level of electromagnetic interference and radio frequency interference attenuation provided by the device, measured in dB.
- Yes
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Alarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 120 V
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- PowerPanel
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 151 mm
- DepthThe distance from the front to the back of something.
- 394 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 225 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 13.1 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- NOM
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- Phone (RJ-11), USB cable
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 10 - 90%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 1500 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 7 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 15 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–15R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA 5-15P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 2
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 45 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 241 mm
- Package depthThe distance from the front to the back of the packaging.
- 510 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 313 mm
- Package weightWeight of the packaged product.
- 14.6 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

CyberPower OL10KRTHW uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W 1 AC outlet(s)
Specs & where to buy

CyberPower UT1050EI uninterruptible power supply (UPS) Line-Interactive 1.05 kVA
630 W 4 AC outlet(s)
Specs & where to buy

CyberPower UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 4 AC outlet(s)
Specs & where to buy

CyberPower OL6KRTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W 10 AC outlet(s)
Specs & where to buy

CyberPower BR700ELCD-FR uninterruptible power supply (UPS) Line-Interactive 0.7 kVA
420 W 8 AC outlet(s)
Specs & where to buy

CyberPower OL6KRT uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W 4 AC outlet(s)
Specs & where to buy