APC Rack PDU, Basic, 1U, 14.4kW, 208V, (6) C19
- Total carbon footprint (kg of CO2e): 23327.5911925625
- Preferred mounting position: no preference
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
It is a basic rack PDU with a 1U horizontal mounting design. It supports a maximum input current of 50A and operates at 200-208V. The PDU features 6 IEC 60320 C19 outlets and is equipped with a CS8365 input connector. It has an 8-foot (2.44 meters) power cord for flexible installation. The unit is designed to fit in a 1U rack space. It is compliant with RoHS and REACh regulations, ensuring it meets environmental standards.
Enables a quick recovery from overload events.
Leveling feet can be quickly adjusted through the use of a screwdriver or drill, eliminating the need to reach underneath with a wrench.
Documents
- DocumentEU Declaration of Conformity ↗
- DocumentEU Declaration of Conformity ↗
- DocumentProduct Environmental Profile (PEP) ↗
- DocumentProduct End of Life Instructions ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 23327.5911925625
- Preferred mounting positionThe recommended orientation or location for installing the unit to ensure optimal performance and stability (e.g. wall, ceiling, or desk).
- no preference
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Waste Electrical and Electronic Equipment (WEEE) complianceIndicates whether the product complies with the Waste Electrical and Electronic Equipment (WEEE) directive regarding the disposal and recycling of electronic waste.
- Yes
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS, REACH, WEEE
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- cUL listed; METI Denan; UL listed
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 3 phases
Show all 31 specificationsShow key specifications only
Features
- Country of originCountry where the device is made. Aka Country of manufacture (COM).
- India
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 200 V; 208 V
- Cable lengthHow long the cable is.
- 2.4 m
- Rack capacityThe spase that device fill in rack.
- 1U
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 23327.5911925625
Technical details
- Sustainable packagingIndicates whether the product is delivered in packaging made from environmentally friendly or recycled materials.
- No
- Packaging recycled materialsIdentifies which specific recycled or secondary material types are present in the packaging.
- Recycled cardboard
- Halogen freeIndicates whether the materials used in the product are free from halogens to prevent the release of toxic gases during combustion.
- No
- Preferred mounting positionThe recommended orientation or location for installing the unit to ensure optimal performance and stability (e.g. wall, ceiling, or desk).
- no preference
- Take-back systemTake-back system allow consumers to return used products to manufacturers or retailers for reuse, recycling, or responsible disposal.
- No
- Packaging without single use plasticIndicates whether the product is delivered in packaging that does not contain any single-use plastics.
- No
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 437 mm
- DepthThe distance from the front to the back of something.
- 254 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 7.98 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
Certificates
- Waste Electrical and Electronic Equipment (WEEE) complianceIndicates whether the product complies with the Waste Electrical and Electronic Equipment (WEEE) directive regarding the disposal and recycling of electronic waste.
- Yes
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS, REACH, WEEE
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- cUL listed; METI Denan; UL listed
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 3 phases
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 3
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 50 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 40 A
Other features
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- Hubbell CS8365C
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- (6) IEC 320 C19
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Logistics data
- Customs product code (TARIC)The integrated Tariff of the European Union code used to identify the product for customs and trade purposes.
- 8544429090
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Rack PDU, Switched, Zero U, 11kW, 230V
(21) C13, (3) C19 power distribution unit (PDU) Black

APC Basic Rack 1.92kVA power distribution unit (PDU) Black

APC Rack PDU, Metered, Zero U, 11kW, 230V
(36) C13 & (6) C19 power distribution unit (PDU) Yes Black

APC Basic Rack 4160VA power distribution unit (PDU) Black

APC Rack PDU, Basic, Zero U, 11 kW, 230V
(36) C13 & (6) C19 power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC Basic Rack 5.7k VA PDU power distribution unit (PDU) 42 AC outlet(s) 0U Black
Accessories & compatible products

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1200D mm

APC NetShelter SX, Networking Rack Enclosure, 42U, 1991H x
750W x 1200D mm, with Sides, Black

APC NetShelter SX Advanced Rack, High Strength, 52U, 2436H x
750W x 1470D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, 42U
800mm 1295mm, with shock package, Black Freestanding rack

APC NetShelter NetShelter SX Gen 2, Front Door Replacement, 42U
750mm Wide, Black

APC Easy Rack, 42U, Black, With Roof, Castors, Feet, 4 Brackets, and Side Panels, No Bottom, 1991H x
600W x 1000D mm