APC Rack PDU, Basic, Zero U, 11 kW, 230V, (36) C13 & (6) C19 power distribution unit (PDU) 42 AC outlet(s) 0U Black
- AC outlets quantity: 42 AC outlet(s)
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
- Certification: C-tick,CCC,CE,GOST,MIC,Queensland Australia,VD
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Basic Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 16A 3P+N+PE , Cord Length: 3 feet ( 0.91 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19.
- Low Cost Power Distribution.
- Vertical mounting capability.
- Toolless mounting capability.
- Multi-branch power input.
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 42 AC outlet(s)
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick,CCC,CE,GOST,MIC,Queensland Australia,VD
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 47/63 Hz
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 11040 VA
Show all 25 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 42 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 44 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1619 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 5.45 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick,CCC,CE,GOST,MIC,Queensland Australia,VD
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 400 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 47/63 Hz
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 11040 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 16 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 16 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 11000 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- IEC 309 16A 3P+N+PE
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- (36) IEC 320 C13 (6) IEC 320 C19
Features
- Cable lengthHow long the cable is.
- 0.91 m
- Rack capacityThe spase that device fill in rack.
- 0U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Smart-UPS On-Line, 10kVA/10kW, Rackmount 6U, 230V/400V, 4x 32A IEC outlets, Network Card+SmartSlot, Extended runtime, W/ custom PDU, W/ rail kit
Specs & where to buy

APC WW 10KVA Isolation Transformer
Specs & where to buy

APC Rack PDU, Metered, Zero U, 11kW, 230V
(36) C13 & (6) C19 power distribution unit (PDU) Yes Black
Specs & where to buy

APC InfraStruXure PDU 60kW 400V/400V power distribution unit (PDU) Black
Specs & where to buy

APC Rack PDU, Switched, Zero U, 11kW, 230V
(21) C13, (3) C19 power distribution unit (PDU) Black
Specs & where to buy

APC InfraStruXure PDU 60kW power distribution unit (PDU) Black
Specs & where to buy
Accessories & compatible products

APC NetShelter SX, Server Rack Enclosure, 48U, White, 2258H x
600W x 1070D mm
Specs & where to buy

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1070D mm
Specs & where to buy

APC Wired, Sensor, NetBotz, Vibration, 12 ft
Specs & where to buy

APC Wired, Sensor, NetBotz, Leak Rope Extension, 20 ft
Specs & where to buy

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1200D mm
Specs & where to buy

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
750W x 1200D mm
Specs & where to buy