APC NetShelter Rack PDU Advanced power distribution unit (PDU) 40 AC outlet(s) 0U Black
- AC outlets quantity: 40 AC outlet(s)
- Operating temperature (T-T): -5 - 60 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
- Operating altitude: 0 - 3048 m
All 51 specificationsProduct page at apc.com ↗
Versions
Metered
Metered, Switched
Switched
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC NetShelter Rack PDU Advanced, Metered, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Maximum Outlet Density
All models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.
Space Saving
With such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.
High Power Capacity
Models now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.
APC Locking Power Cord Compatible
Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.
Circuit Breaker Monitoring
Allows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.
Alternating Phase
NetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.
60ºC (140ºF) Operating Temperature
Rated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.
Power Sharing
Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.
Hydraulic Magnetic Circuit Breakers
Provide increased availability by maintaining trip current over a wide temperature range.
Live Swap Network Management Card
The Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.
Color Coded Outlets
To simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.
Environmental Sensor Support
Two environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.
Wide Offer Breadth
Metered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.
Network Cascading
Connect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.
US Based Manufacturing
US based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.
Dual Rated
For data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
- DocumentAPC NetShelter Rack PDU Advanced Technical Specs ↗
- DocumentAPC NetShelter Rack PDU Advanced End User 1 Pager ↗
- DocumentAPC NetShelter Rack PDU Advanced Brochure ↗
- DocumentAPC NetShelter Rack Power Distribution Pocket Guide featuring NetShelter Rack PDU Advanced NAM ↗
- DocumentAPC NetShelter Rack PDU Advanced Metered 5.0kW 1PH 208V 30A L6-30P_40 Outlet ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 40 AC outlet(s)
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 200-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
Show all 51 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 40 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-30P
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C15 coupler, C19 coupler, C21 coupler
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
- USB ports quantityThe total number of available Universal Serial Bus (USB) connection interfaces on the device.
- 1
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 75 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1490 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 6.6 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 200-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 30 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 4992 VA
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 24 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
- Maximum powerThe maximum power that can be put into or produced by the device.
- 5000 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
- Compatible productsOther products that can be used with this product.
- Compatible with most NetShelter SX enclosures and third-party racks
- Regulatory ApprovalsLists the official certifications and compliance standards the product has met for legal sale and operation in various regions.
- CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Features
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Colour-coded outletsIndicates whether the device features outlets that are visually distinguished by different colours to help identify power sources or phases.
- Yes
- Cable lengthHow long the cable is.
- 3 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Humidity, Power, Temperature, Voltage
- Outlet controlSpecifies the available management actions for individual power sockets, such as the ability to recycle or lock-out a port (e.g., Turn on, Turn off).
- Lock-out, Recycle, Turn off, Turn on
- Firmware upgradeableIndicates whether the internal software of the device can be updated to a newer version to improve performance or add features.
- Yes
- Firmware upgradeable viaThe method or interface used to update the internal system software of the device (e.g., via USB, Network, or a Web Interface).
- Network, USB
Performance
- Daisy chainIndicates whether the product supports connecting multiple units in a series to a single output source.
- Yes
- Reset buttonIndicates whether the device features a dedicated button to restore the unit to its original factory settings.
- Yes
- Security algorithmsSecurity algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.
- 128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
- On/off switchThe button which is pressed to switch the device on or off.
- Yes
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Activity, Network, Power
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered
- Form factorThe shape or design of the product.
- Rackmount
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Security
- Password protectionThe computer, smartphone etc. can only be used when the correct password is entered, therefore making it more secure.
- Yes
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Packaging data
- Package weightWeight of the packaged product.
- 8.6 kg
- Package widthThe distance from one side of the packaging to the other.
- 208 mm
- Package depthThe distance from the front to the back of the packaging.
- 116 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1720 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309

APC APDU10351SW power distribution unit (PDU) 24 AC outlet(s) 0U Black

APC APDU10451SW power distribution unit (PDU) 42 AC outlet(s) Black

APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

APC APDU10351SM power distribution unit (PDU) 48 AC outlet(s) 0U Black