APC APDU10351SM power distribution unit (PDU) 48 AC outlet(s) 0U Black
- AC outlets quantity: 48 AC outlet(s)
- Operating temperature (T-T): 23 - 140 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
- Operating altitude: 0 - 3048 m
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 8.6kW, 3PH, 208V 30A, L21-30P, 48 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Documents
- ManualUser manual ↗
- DocumentNetShelter Rack PDU Advanced Installation & Quick Start ↗
- DocumentNAM APC NetShelter Rack Power Distribution Pocket Guide featuring NetShelter Rack PDU Advanced ↗
- DocumentAPC NetShelter Rack PDU Advanced Brochure ↗
- DocumentEnd User Brochure APC NetShelter Rack PDU Advanced ↗
- Document1 Pager with specs APC NetShelter Rack PDU Advanced ↗
- DocumentAPDU10351SM-APC NetShelter Rack PDU Advanced Switched Metered Outlet 8.6kW 3PH 208V 30A L21-30P_48 Outlet ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 48 AC outlet(s)
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 23 - 140 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
Show all 33 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 48 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C15 coupler, C19 coupler, C21 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 75 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1780 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 9.4 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 23 - 140 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 24 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 8600 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 30 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 24 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
Features
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 208 V
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Performance
- Daisy chainIndicates whether the product supports connecting multiple units in a series to a single output source.
- Yes
- On/off switchThe button which is pressed to switch the device on or off.
- No
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Packaging data
- Package weightWeight of the packaged product.
- 12.4 kg
- Package widthThe distance from one side of the packaging to the other.
- 208 mm
- Package depthThe distance from the front to the back of the packaging.
- 116 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1980 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC APDU10451ME power distribution unit (PDU) 42 AC outlet(s) Black

APC APDU10451SW power distribution unit (PDU) 42 AC outlet(s) Black

APC APDU10452SW power distribution unit (PDU) 42 AC outlet(s) Black

APC NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309

APC NetShelter Rack PDU Advanced, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309