APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black
- AC outlets quantity: 8 AC outlet(s)
- Total carbon footprint (kg of CO2e): 915.89
- Operating temperature (T-T): 0 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
- DocumentInstallation ↗
- DocumentDrawing ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 915.89
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 1 - 15000 m
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 200-230 V
Show all 37 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C20 coupler
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 915.89
Packaging content
- Packaging contentA list of all items and documentation included in the box (e.g. Quick Start Guide).
- Installation Guide, Rack Mounting Brackets, User Manual
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 445 mm
- DepthThe distance from the front to the back of something.
- 108 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 44 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 2.27 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 1 - 15000 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 200-230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 3680 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 16 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 16 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 3680 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208-230 V
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- IEC-320 C20
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Voltage
- Outlet controlSpecifies the available management actions for individual power sockets, such as the ability to recycle or lock-out a port (e.g., Turn on, Turn off).
- Lock-out, Recycle, Turn off, Turn on
Features
- Cable lengthHow long the cable is.
- 2.5 m
- Rack capacityThe spase that device fill in rack.
- 0U/1U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Packaging data
- Package weightWeight of the packaged product.
- 3.45 kg
- Package widthThe distance from one side of the packaging to the other.
- 470 mm
- Package depthThe distance from the front to the back of the packaging.
- 343 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 70 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Smart-UPS On-Line, 10kVA/10kW, Rackmount 6U, 230V/400V, 4x 32A IEC outlets, Network Card+SmartSlot, Extended runtime, W/ custom PDU, W/ rail kit

APC NetShelter Switched Rack PDU, 1U, 1PH, 2.3kW 230V 10A or 2.5kW 208V 12A, 8 C13 outlets, C14 cord

APC AP7822B power distribution unit (PDU) 16 AC outlet(s) 2U Black

APC AP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black

APC NetShelter Switched Rack PDU, 1U, 1.4kW, 120V, 15A, 8 NEMA 5-15R outlet

APC AP8967 power distribution unit (PDU) 48 AC outlet(s) Black
Accessories & compatible products

APC NetShelter SX, Server Rack Enclosure, 48U, White, 2258H x
600W x 1070D mm

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1070D mm

APC Wired, Sensor, NetBotz, Vibration, 12 ft

APC Power Cord Kit
(6 ea), Locking, C13 to C14, 1.8m

APC Wired, Sensor, NetBotz, Leak Rope Extension, 20 ft

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1200D mm