APC AP7822B power distribution unit (PDU) 16 AC outlet(s) 2U Black
- AC outlets quantity: 16 AC outlet(s)
- Total carbon footprint (kg of CO2e): 8952.07
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log amperage to support real-time monitoring and historical reporting. This PDU remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. The historical reporting enables users to optimize energy use and plan for capacity with confidence. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 200-230 volts via IEC 309 plug with a 3.6m (11 ft) cord while power comes out at 230 volts through (36) IEC 320 C13 and (6) IEC 320 C19 outlets. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 16 AC outlet(s)
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 8952.07
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick, CE, FCC 15 A, GOST, ICES-003, IRAM, MIC, VDE, VCCI
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208-230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
Show all 37 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 16 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC309
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 8952.07
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 444 mm
- DepthThe distance from the front to the back of something.
- 112 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 88 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.36 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- C-tick, CE, FCC 15 A, GOST, ICES-003, IRAM, MIC, VDE, VCCI
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208-230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 32 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 7680 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 32 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 32 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
- Maximum powerThe maximum power that can be put into or produced by the device.
- 7680 W
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Voltage
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Cable lengthHow long the cable is.
- 3.66 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 2U
Other features
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- IEC 309 32A 2P+E
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 12 x C13 4 x C19
Performance
- On/off switchThe button which is pressed to switch the device on or off.
- Yes
Packaging data
- Package weightWeight of the packaged product.
- 5.41 kg
- Package widthThe distance from one side of the packaging to the other.
- 508 mm
- Package depthThe distance from the front to the back of the packaging.
- 368 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 140 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Smart-UPS On-Line, 10kVA/10kW, Rackmount 6U, 230V/400V, 4x 32A IEC outlets, Network Card+SmartSlot, Extended runtime, W/ custom PDU, W/ rail kit

APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

APC NetShelter Switched Rack PDU, 1U, 1.4kW, 120V, 15A, 8 NEMA 5-15R outlet

APC NetShelter Switched Rack PDU, 1U, 1PH, 2.3kW 230V 10A or 2.5kW 208V 12A, 8 C13 outlets, C14 cord

APC SPD20KCBL power distribution unit (PDU) 13 AC outlet(s) Black

APC AP7811B power distribution unit (PDU) 16 AC outlet(s) 2U Black
Accessories & compatible products

APC NetShelter SX, Server Rack Enclosure, 48U, White, 2258H x
600W x 1070D mm

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1070D mm

APC Wired, Sensor, NetBotz, Vibration, 12 ft

APC Power Cord Kit
(6 ea), Locking, C13 to C14, 1.8m

APC Wired, Sensor, NetBotz, Leak Rope Extension, 20 ft

APC NetShelter SX, Server Rack Enclosure, 45U, White, 2124H x
600W x 1200D mm