AEG Protect Home 600 FR uninterruptible power supply (UPS) Standby (Offline) 0.6 kVA 300 W 4 AC outlet(s)
- Product colour: Black
- UPS topology: Standby (Offline)
- Output power capacity: 0.6 kVA
- Output power: 300 W
- Number of phases: 1
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Protect Home offers high availability with overload and excess voltage and surge protection for PC, Mac, telephone, faxe and modem via direct connection to the UPS outlets. LED and audible alarm notification provides clear information about the most important operating conditions. Via the USB or RS232 interface a PC can be connected to operate using the “CompuWatch” software.
- Rugged UPS technology for power outages, voltage fluctuations and spikes
- USB and RS232 interface for control and management for PC and MAC
- Fully fledged “CompuWatch” “plug & play” software
- Data line protection (telephone, fax and modem)
- User friendly battery design
- Individual operation, wall mountable
- 1 output for connecting consumers with high power requirements such as laser printers
Specifications
Key specifications
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Standby (Offline)
- Output power capacityThe maximum power that the device can produce.
- 0.6 kVA
- Output powerThe power that the device can produce.
- 300 W
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
- AC outlet typesThe type of outlet for AC electricity.
- Type E
Show all 27 specificationsShow key specifications only
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Standby (Offline)
- Output power capacityThe maximum power that the device can produce.
- 0.6 kVA
- Output powerThe power that the device can produce.
- 300 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (max)The maximum input voltage supported by the device.
- 230 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Fax, Modem, Telephone
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 3 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 137 mm
- DepthThe distance from the front to the back of something.
- 310 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 96 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.5 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Type E
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

AEG Protect NAS uninterruptible power supply (UPS) Line-Interactive 0.5 kVA
250 W 4 AC outlet(s)

AEG Protect alpha 1200 uninterruptible power supply (UPS) 1.2 kVA
600 W 6 AC outlet(s)

AEG Protect B. 500 uninterruptible power supply (UPS) Line-Interactive 0.5 kVA
350 W 4 AC outlet(s)

AEG Protect alpha 450 uninterruptible power supply (UPS) 0.45 kVA
240 W 4 AC outlet(s)

AEG Protect B. 750 uninterruptible power supply (UPS) Line-Interactive 0.75 kVA
450 W 4 AC outlet(s)

AEG Protect C.2000 + Battery Pack uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1600 W 5 AC outlet(s)