AEG Protect B. 750 uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 450 W 4 AC outlet(s)
- Product colour: Black, Silver
- UPS topology: Line-Interactive
- Output power capacity: 0.75 kVA
- Output power: 450 W
- Number of phases: 1
- Resource CD
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The new Protect B series has been specially refined for applications in the SME and SoHo segment and is perfect for protecting NAS systems, ATMs, 3D printers, workstations, PCs, and other IT applications. In particular, the standard HID power device interface enables software-independent communication and allows the UPS to be integrated directly into a network-attached storage (NAS) management system. The Protect NAS model also has a much longer autonomy time in the lower partial load range when operated fanless. This makes the Protect NAS ideal for office and home environments.
Protect B / NAS - Description
The VI (line interactive) technology of the Protect B provides reliable protection for your sensitive company data in the event of power failure, dangerous power surges, and HF interference. More substantial voltage fluctuations are systematically offset via the voltage pre-regulator (AVR) of the Protect B.
More extensive monitoring and management tasks in the IT environment can still be carried out by the AEG “CompuWatch” shutdown software provided.
A redesigned, high-contrast LCD display provides information on all key operating conditions and, in particular, on the remaining autonomy time with the current load and power failure.
The systematically refined hardware design with battery-saving charging electronics guarantees many years of use. The UPS front panel makes it easy to replace the batteries.
Specifications
Key specifications
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 450 W
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Resource CDIndicates whether the product is supplied with a resource compact disc containing drivers or documentation.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Show all 53 specificationsShow key specifications only
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Battery replacement
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.75 kVA
- Output powerThe power that the device can produce.
- 450 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 220 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 94%
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Fax, Modem, Network, Telephone
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Battery replacement
- Auto-restartIndicates whether the device automatically reboots itself after a power failure or a system crash.
- Yes
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 3.9 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload, Short circuit
Packaging content
- Resource CDIndicates whether the product is supplied with a resource compact disc containing drivers or documentation.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 150 mm
- DepthThe distance from the front to the back of something.
- 240 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 209 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 6.8 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 199 mm
- Package depthThe distance from the front to the back of the packaging.
- 301 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 295 mm
- Package weightWeight of the packaged product.
- 7.8 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

AEG Protect B. 1000 uninterruptible power supply (UPS) Line-Interactive 1 kVA
700 W 8 AC outlet(s)

AEG Protect B. 500 uninterruptible power supply (UPS) Line-Interactive 0.5 kVA
350 W 4 AC outlet(s)

AEG Protect B. 1500 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 8 AC outlet(s)

AEG Protect NAS uninterruptible power supply (UPS) Line-Interactive 0.5 kVA
250 W 4 AC outlet(s)

AEG Protect C. 1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
900 W 4 AC outlet(s)

AEG Protect Home 600 FR uninterruptible power supply (UPS) Standby (Offline) 0.6 kVA
300 W 4 AC outlet(s)