AEG Protect C. 1000 (2014) uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 800 W 4 AC outlet(s)
- Form factor: Tower
- Product colour: Black, Silver
- UPS topology: Double-conversion (Online)
- Output power capacity: 1 kVA
- Output power: 800 W
- Number of phases: 1
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The new Protect C UPS from 1000 to 3000 VA power represent consistent further development of the well-proven and highly reliable series. With the lag increased to 0.8, the power factor was taken into account for the demand for higher performance active consumers. The ECO and frequency inverter for operation mode highlights the requirements for a modern versatile UPS.
6 & 10 kVA: Highly integrated switches and a robust IGBT module reduce the number of electrical connections and components and therefore provide for increased reliability. A Static Bypass Switch (SBS) and/or an automated bypass ensure additional safety in case of overload.
- VFI topology (online / double conversion) protection against all mains network problems
- Extremely wide input voltage window of 110 VAC to 300 VAC without stress on the internal battery system and with a stable output voltage
- ECO and frequency operating voltage possible
- Expansion slot for SNMP, potential free contacts, remote display
- Graphic LCD display with interactive multilingual user interface
- Configuration options (password protected) via the operator terminal
- Internal hardware data logger with plain text display and date / time stamp
- Emergency power off on terminal block (potential-free)
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 800 W
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Display typeType of display (screen) e.g. LCD.
- LCD
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
Show all 33 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 1 kVA
- Output powerThe power that the device can produce.
- 800 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 220 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 5%
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 4.6 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overdischarge, Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 145 mm
- DepthThe distance from the front to the back of something.
- 400 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 220 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 13 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.99
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 44 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

AEG Protect C. 2000
(2014) uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1600 W 6 AC outlet(s)

AEG Protect alpha 800 uninterruptible power supply (UPS) 0.8 kVA
480 W 4 AC outlet(s)

AEG Protect C. 3000
(2014) uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2400 W 4 AC outlet(s)

AEG Protect alpha 600 uninterruptible power supply (UPS) 0.6 kVA
360 W 4 AC outlet(s)

AEG Protect C.2000 + Battery Pack uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1600 W 5 AC outlet(s)

AEG Protect B. 3000 PRO BP uninterruptible power supply (UPS) Line-Interactive 3 kVA
2700 W 7 AC outlet(s)