AEG Protect alpha 600 uninterruptible power supply (UPS) 0.6 kVA 360 W 4 AC outlet(s)
- Product colour: Black
- Output power capacity: 0.6 kVA
- Output power: 360 W
- Number of phases: 1
- Operating temperature (T-T): 0 - 40 °C
- Operating relative humidity (H-H): 0 - 90%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Protect alpha series offers effective and economical data protection during power failure, dangerous power surges and voltage fluctuations. Protect alpha proves itself in critical situations with its high availability due to a sturdy overload and excess voltage protection, as well as a wide input voltage range. The reliable “One-Board-Design“ and its strong case makes the Protect alpha the perfect power solution for rough environments. With its easy control and compact dimensions it can be used in various applications. All models are characterized by their microprocessor control, an automatic voltage regulation and their deep discharge protection.
- Modern VI (line-interactive) technology against power failure and dangerous overvoltage
- Automatic voltage regulation against mains voltage deviations (AVR)
- Easy installation ensured by cables supplied and optimum operation
- Use of sealed, maintenance-free lead-acid batteries with exhaustive discharge protection
- USB port communication interface
- Fully fledged “CompuWatch” plug & play software
- Data line protection for phone, fax and modem (RJ11)
- Compact dimensions and light weight
Specifications
Key specifications
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 0.6 kVA
- Output powerThe power that the device can produce.
- 360 W
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 6 h
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
Show all 26 specificationsShow key specifications only
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Output power capacityThe maximum power that the device can produce.
- 0.6 kVA
- Output powerThe power that the device can produce.
- 360 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 170 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 280 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Fax, Modem, Telephone
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 2.6 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 100 mm
- DepthThe distance from the front to the back of something.
- 278 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 143 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4.4 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 6 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Modem (RJ-11) portsThe number of available RJ-11 connectors used for connecting telephone lines to the device.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

AEG Protect alpha 800 uninterruptible power supply (UPS) 0.8 kVA
480 W 4 AC outlet(s)

AEG Protect B. 3000 PRO BP uninterruptible power supply (UPS) Line-Interactive 3 kVA
2700 W 7 AC outlet(s)

AEG Protect C. 1000
(2014) uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 800 W 4 AC outlet(s)

AEG Protect B. 1000 PRO BP uninterruptible power supply (UPS) Line-Interactive 1 kVA
900 W 8 AC outlet(s)

AEG Protect C. 2000
(2014) uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1600 W 6 AC outlet(s)

AEG Protect B. 1800 PRO BP uninterruptible power supply (UPS) Line-Interactive 1.8 kVA
1620 W 8 AC outlet(s)