ATEN EC2004 power distribution unit (PDU) 4 AC outlet(s) 1U

ATEN EC2004 power distribution unit (PDU) 4 AC outlet(s) 1U

ATENGrenuttagModell EC2004
  • Antal uttag AC: 4 AC-utgångar
  • Storlek: 16,2 m (637,6")
  • Temperatur vid drift: 0 - 50 ° C
  • Temperaturintervall (förvaring): -20 - 60 ° C
  • Intervall för relativ operativ luftfuktighet: 0 - 80%
  • Ingångsspänning (Volt): 100 V

Alla 17 specifikationerProduktsida på aten.com ↗

Var du köper

Vi bevakar inte priser för den här produkten än. Se aktuella priser direkt hos:

Vi kan få provision när du köper via länkar på den här sidan — utan extra kostnad för dig. Läs mer

Om produkten

The EC2004 Energy Box is the latest evolution of ATEN's energy intelligence solutions. EC2004 Energy Boxes provides instant real-time power management and energy-saving control for data centers– allowing you to upgrade and maintain your current IT power resources quickly and cost-effectively.

The EC2004 Energy Box has four Energy Sensor ports (2 Current Energy Sensors, 2 Current/Voltage Energy Sensors) to connect to four Energy PDU modules, four Environment Sensor ports and one 4-pin dry contact Rack Door Sensor port, these external sensors can monitor environmental conditions and rack door access. Each environmental sensor can provide measured readings of temperature, humidity, and differential pressure from separate areas of a room, giving a wide range of monitoring and protection you need.

The EC2004 Energy Box features real-time status, system logs, threshold alerts, and event notifications. The EC2004 logs power and environmental conditions according to customizable minimum/maximum thresholds set for electrical current, voltage, temperature, humidity, and differential pressure.

The EC2004 Energy Box allows power and environmental data to be monitored by display at the rack or remotely for easy viewing and maintenance. The Energy Box is a standalone unit with Over IP monitoring that is controlled by ATEN´s eco DC Web GUI.

Remote monitoring offers secure access with 128bits SSL encryption, and customizable account policies for user management. Remote authentication supports RADIUS and additional management interfaces including HTTP, HTTPS, and SNMPv1&v2&v3 (Read, Write, Trap). Event notifications can be monitored via Syslog/SMTP/ SNMP trap and audible alarms for real-time local and remote alerting.

When used in conjunction with ATEN's Energy PDUs* and eco Sensors Energy Management Software*, the EC2004 allows you to conveniently upgrade your cabinet with remote energy management functionality to make your server room go green quickly and cost-effectively.

* ATEN series of low cost Energy PDUs (PE2220/PE2340) and energy management Web GUI – eco DC are available at www.aten.com.

Dokument

Specifikationer

Anslutningar

Antal uttag AC
4 AC-utgångar

Vikt & dimension

Bredd
2000 mm
Djup
759 mm
Höjd
420 mm
Vikt
640 g
Storlek
16,2 m (637,6")

Miljökrav

Temperatur vid drift
0 - 50 ° C
Temperaturintervall (förvaring)
-20 - 60 ° C
Intervall för relativ operativ luftfuktighet
0 - 80%

Strömtillförsel

Ingångsspänning (Volt)
100 V
Växelström Frekvens
50 hz
Högsta strömstyrka
32 A

Management features

Övervakning
Strömstyrka, Luftfuktighet, Temperatur, Spänning

Design

LED-indikatorer
LAN

Övrigt

Kompatibla produkter
CC2000 3.0 EA1442 EA1340 EA1441 EA1440 EA1240 EA1140 CC2000

Funktioner

Rackkapacitet
1U

Display

Displaytyp
LED

Database Right data-sheet 2026 Icecat. All rights reserved. Tillhandahålls ”i befintligt skick”, utan garanti — kontrollera detaljerna med butiken innan du köper.