APC AP8966 power distribution unit (PDU) 32 AC outlet(s) 0U Black
- Antal uttag AC: 32 AC-utgångar
- Temperatur vid drift: 0 - 45 ° C
- Temperaturintervall (förvaring): -25 - 65 ° C
- Intervall för relativ operativ luftfuktighet: 5 - 95%
- Fuktighet (förvaring): 5 - 95%
- Altitud vid drift: 0 - 3000 m
Var du köper
Vi bevakar inte priser för den här produkten än. Se aktuella priser direkt hos:
Vi kan få provision när du köper via länkar på den här sidan — utan extra kostnad för dig. Läs mer
Om produkten
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Dokument
- BroschyrProduct Brochure ↗
Specifikationer
Viktigaste specifikationer
- Antal uttag ACChipset för denna konfiguration, uttryckt som tillverkare och myntade namnet
- 32 AC-utgångar
- Temperatur vid drift
- 0 - 45 ° C
- Temperaturintervall (förvaring)
- -25 - 65 ° C
- Intervall för relativ operativ luftfuktighet
- 5 - 95%
- Fuktighet (förvaring)
- 5 - 95%
- Altitud vid drift
- 0 - 3000 m
- Höjd över havet i avstängt läge
- 0 - 15000 m
- Certifikat för överensstämmelse
- RoHS
- Ingångsspänning (Volt)
- 208 V
- Växelström Frekvens
- 50 - 60 hz
Visa alla 34 specifikationerVisa bara de viktigaste specifikationerna
Anslutningar
- Antal uttag ACChipset för denna konfiguration, uttryckt som tillverkare och myntade namnet
- 32 AC-utgångar
- Uttag
- IEC 60309
- AC försäljningsställen
- C13 coupler, C19 coupler
Vikt & dimension
- Bredd
- 56 mm
- Djup
- 51 mm
- HöjdHöjd av produkten
- 1829 mm
- ViktProduktens vikt utan förpackning (nettovikt). Om möjligt nettovikten är angett inklusive standardtillbehör och förråd.Obs, ibland anger tillverkaren en för kommersiell interpretation av produktvikten, där han lämnar ut vikten av tillbehör och/eller förråd.
- 15,9 kg
Miljökrav
- Temperatur vid drift
- 0 - 45 ° C
- Temperaturintervall (förvaring)
- -25 - 65 ° C
- Intervall för relativ operativ luftfuktighet
- 5 - 95%
- Fuktighet (förvaring)
- 5 - 95%
- Altitud vid drift
- 0 - 3000 m
- Höjd över havet i avstängt läge
- 0 - 15000 m
Certifikat
- Certifikat för överensstämmelse
- RoHS
- Certifiering
- cUL Listed, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A, REACH, PEP, EOLI
Strömtillförsel
- Ingångsspänning (Volt)
- 208 V
- Växelström Frekvens
- 50 - 60 hz
- Högsta strömstyrka
- 60 A
- Belastningskapacitet
- 17300 VA
- Maximal strömförbrukning per fasAntal och typ av spår minnesexpansion, inklusive kontakt och minne modul beskrivningar
- 48 A
- Maximal sammanlagd strömförbrukning per fas
- 48 A
- Effekt skyddsfunktioner
- Överbelastning
Övrigt
- Utspänning (Volt)
- 208 V
Management features
- Övervakning
- Strömstyrka
Design
- LED-indikatorer
- Ja
- PDU typer
- Kopplad
- Montage
- Horisontell / Vertikal
- Produktens färg
- Svart
Funktioner
- Kabellängd
- 1,83 m
- Rackkapacitet
- 0U
Förpackning
- Vikt inkl. förpackningVikt av den förpackade produkten i gram.
- 20 kg
- Förpackningens breddEn lista med vilka tjänster och mjukvaror som följer med produkten
- 221 mm
- LåddjupFör att visa hur mycket som kan bli skrivit eller läst på tejpen
- 112 mm
- Förpackningens höjdTjockleken på tejpen är uttryckt i microner
- 2149 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Tillhandahålls ”i befintligt skick”, utan garanti — kontrollera detaljerna med butiken innan du köper.
Prishistorik (90 dagar, bästa dagspris)
Vi samlar fortfarande in prishistorik för den här produkten — titta in igen snart.
Alternativa modeller

APC AP7802B power distribution unit (PDU) 16 AC outlet(s) 2U Black

APC NetShelter Switched Rack PDU, Zero U, 12.5kW, 208V, 21 C13 and 3 C19 outlet, 3ft input cord

APC Rack PDU, Switched, 2U, 30A, 120V
(16)5-20

APC Rack PDU, Switched, 2U, 30A, 208V
(16)C13

APC AP7801B power distribution unit (PDU) 8 AC outlet(s) 1U Black