Eaton FLXTBA116C2 power distribution unit (PDU) 24 AC outlet(s) 0U
- AC outlets quantity: 24 AC outlet(s)
- Nominal input voltage: IEC60309 16A
- Maximum current: 16 A
- Maximum power: 3700 W
- Cable length: 3 m
- Power plug: IEC 60309
Gdzie kupić
Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:
Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej
O produkcie
Eaton FlexPDU G2 provides a range of standardized rack power distribution units (PDUs), including basic, metered input, switched, and managed models, designed to enhance the safety, manageability, and energy efficiency across edge facilities and distributed IT infrastructure.
Specyfikacja
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC 60309
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- IEC60309 16A
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 3700 W
Features
- Cable lengthHow long the cable is.
- 3 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic, Managed, Metered, Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.
Historia cen (90 dni, najlepsza cena dnia)
Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.
Alternatywne modele

Eaton FLEXPDU G2 BA 1U 1P 16A C20 power distribution unit (PDU) 8 AC outlet(s) Black
Specyfikacja i gdzie kupić

Eaton FLXTMIC14C1 power distribution unit (PDU) 8 AC outlet(s) 1U Black
Specyfikacja i gdzie kupić

Eaton FLXTMI116C2 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specyfikacja i gdzie kupić

Eaton FLEXPDU G2 BA 1U 1P 10A C14 power distribution unit (PDU) 8 AC outlet(s) Black
Specyfikacja i gdzie kupić

Eaton EHMAL620N power distribution unit (PDU) 8 AC outlet(s) 1U Black
Specyfikacja i gdzie kupić

Eaton EHMAGU23A power distribution unit (PDU) 24 AC outlet(s) 2U Black
Specyfikacja i gdzie kupić