Eaton EVMOGU23A-E power distribution unit (PDU) 24 AC outlet(s) 0U Black
- AC outlets quantity: 24 AC outlet(s)
- Operating temperature (T-T): 0 - 60 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Nominal input voltage: 240 - 415 V
- AC input frequency: 50 - 60 Hz
Gdzie kupić
Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:
Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej
Dokumenty
- BroszuraProduct Brochure ↗
Specyfikacja
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C39 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 51 mm
- DepthThe distance from the front to the back of something.
- 1420 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 65 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 5.08 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 240 - 415 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 55 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 23000 VA
- Maximum powerThe maximum power that can be put into or produced by the device.
- 23000 W
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered-by-outlet
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Housing materialWhat the casing of the product is made of.
- Aluminium
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- TypeCharacteristics of the device.
- Three-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.
Historia cen (90 dni, najlepsza cena dnia)
Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.
Alternatywne modele

Eaton metered outlet PDU, universal input PDU, 42 outlet, 72in, front entry cable input
Specyfikacja i gdzie kupić

Eaton EVMOGU23X-E power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specyfikacja i gdzie kupić

Eaton 9PXPPDM2G2 power distribution unit (PDU) 3U Black
Specyfikacja i gdzie kupić

Eaton EMAU16-10 power distribution unit (PDU) 24 AC outlet(s) 2U Black
Specyfikacja i gdzie kupić

Eaton 9PXTFMR5G2 power distribution unit (PDU) 3U Black, Grey
Specyfikacja i gdzie kupić

Eaton EVMA1530A power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specyfikacja i gdzie kupić