CyberPower SMBCB250 circuit breaker Residual-current device 3
- Circuit breaker type: Residual-current device
- Rated current: 250 A
- Operating temperature (T-T): -35 - 70 °C
- Operating relative humidity (H-H): 0 - 90%
- Number of poles: 3
- Rated voltage: 250 V
Gdzie kupić
Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:
Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej
O produkcie
3-Phase Modular UPS Circuit Breaker provides overcurrent protection to safeguard electrical device. The circuit breaker will automatically trip to switch off power supply when overcurrent or short-circuit occurs. Its fuse with high breaking capacity up to 50kA is able to withstand large instantaneous current to ensure safe power distribution.
Dokumenty
- BroszuraProduct Brochure ↗
Specyfikacja
Features
- Circuit breaker typeThe specific design and functional category of the protection device, such as a Miniature circuit breaker or a Residual-current device.
- Residual-current device
- Number of polesThe number of electrical poles or phases the device is designed to connect or switch (e.g., 1P, 3P).
- 3
Power
- Rated currentThe maximum amount of electric current the device is designed to carry continuously under specified conditions, measured in amperes.
- 250 A
- Rated voltageThe specified electrical potential difference at which the device is designed to operate, measured in volts.
- 250 V
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 107 mm
- DepthThe distance from the front to the back of something.
- 109 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 165 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 2.28 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -35 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.
Historia cen (90 dni, najlepsza cena dnia)
Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.
Alternatywne modele

CyberPower SMBCB125 circuit breaker Molded case circuit breaker 3

CyberPower 100A circuit breaker Miniature circuit breaker 3

Eaton PXF-25/4/003-A circuit breaker Residual-current device

CyberPower SMUCB175UAC circuit breaker Miniature circuit breaker 3

Eaton PXL-C4/1 circuit breaker Miniature circuit breaker