CyberPower OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 5400 W 13 AC outlet(s)

CyberPower OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 5400 W 13 AC outlet(s)

CyberPowerZasilacze UPSModel OL6000RT3UPDUTF
  • Układ: Rackmount/Tower
  • Kolor produktu: Czarny
  • Topologia UPS: Podwójnej konwersji (online)
  • Maksymalna możliwa do konfiguracji moc: 6 kVA
  • Moc rzeczywista: 5400 W
  • Certyfikaty zgodności: RoHS

Wszystkie parametry (59)Strona produktu na cyberpowersystems.com ↗

Gdzie kupić

Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:

Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej

O produkcie

The CyberPower Smart App Online OL6000RT3UPDUTF is an 8U rack/tower UPS with double-conversion topology, Maintenance Bypass Switch, and Step-Down Transformer. It provides sine wave output to mission-critical applications and equipment requiring seamless power protection. Generator-compatible, the OL6000RT3UPDUTF delivers consistent and clean 120V or 200-240V AC power with zero transfer time. Auto-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The Maintenance Bypass Switch allows for the UPS power module to be hot-swapped for service or replacement without cutting power to the connected equipment.

The OL6000RT3UPDUTF features an extendable LCD control panel (with optional cable), Smart Battery Management charging design, Fast Charge Technology, and the energy-saving GreenPower UPS ECO Mode. This model can use the BP240V30ART3U Extended Battery Module for expanded runtime and faster restoration of full backup power. The OL6000RT3UPDUTF comes with a three-year warranty (including batteries) and a $300,000 Connected Equipment Guarantee.

Data Line Protection

Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.

Double-Conversion Topology

Provides consistent, clean, and nearly perfect sine wave power, regardless of the condition of incoming power. Systems with this technology operate on isolated DC power 100% of the time and have a zero transfer time because they never need to switch to battery. Double-Conversion UPS systems are designed for high-end, mission-critical system components, corporate servers, lab equipment, and other sensitive electronic devices.

Sine Wave Output

Provides power protection to ENERGY STAR 6.0 systems with Active PFC power supplies.

Step-Down Transformer

Supports 120V and 200-240V output requirements with a single UPS solution. With six (6) NEMA 5-20R outlets available, users will have sufficient outlets to connect multiple 120V devices running at 15A and/or 20A. (A CyberPower PDU can be purchased if additional outlets are required.)

Maintenance Bypass Switch

Provides IT managers the ability to service or replace the UPS without powering down the connected equipment. A patented interlock bracket enables the UPS to automatically switch to internal bypass mode, making the hot-swap process easier and quicker to complete.

Extendable LCD Panel

Displays UPS statuses and customizable operating settings. The 43-setting LCD control panel can be removed and mounted up to ten feet away from the UPS (with optional cable). Users can check UPS status, manage setup and control, and run battery test options. Status and log menus provide UPS vitals, including input and output voltage levels, battery information, runtime estimates, load information, event and fault logging, and other system information. The Configuration menu offers IT managers the ability to customize the UPS operation.

Multiple Language Options

The LCD Control Panel can be configured in English, Spanish, French, and German for ease of use.

Extended Battery Module (EBM)

Extends runtime by adding EBMs. An online Series UPS allows for up to ten added modules.

Fast Charge Technology

Allows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM. Restores a complete charge within 5 hours regardless of the number of EBMs.

Smart Battery Management (SBM)

Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process. The first cycle charges the battery to full capacity, the second cycle enters float mode, and the final cycle turns the charger off and allows the battery to naturally discharge (rest) until it reaches a set point. After a slight discharge, the UPS will restart the process, ensuring that runtimes are maintained.

GreenPower UPS ECO Mode

Improves UPS efficiency up to 95%; saves on electrical and cooling costs.

Hot-Swappable Batteries

Eliminate downtime related to UPS power maintenance for continuous power availability.

Critical & Non-Critical Loads

The UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet. Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.

Emergency Power Off (EPO)

Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.

Backfeed Protection

Prevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost. Backfeed protection isolates the UPS and allows service personnel to safely work on the utility power.

Generator Compatible

Provides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.

Converter Mode

Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.

USB & Serial Connectivity

Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.

EMI/RFI Filters

Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.

Audible Alarms

Identify when the unit is running on battery power, overloaded, or has a low battery.

Resettable Circuit Breaker

Interrupts an electric current in a circuit when the current becomes too high.

LED Status Lights

Indicate Power On, On-Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.

Rack/Tower Versatility

Allows for horizontal rack or vertical tower installation.

Dokumenty

Specyfikacja

Najważniejsze parametry

Układ
Rackmount/Tower
Kolor produktu
Czarny
Topologia UPS
Podwójnej konwersji (online)
Maksymalna możliwa do konfiguracji moc
6 kVA
Moc rzeczywista
5400 W
Certyfikaty zgodności
RoHS
Przewody
Seryjny, Kabel USB
Bezpieczeństwo
UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Certyfikat środowiskowy (zrównoważonego rozwoju)
ENERGY STAR
Zakres temperatur (eksploatacja)
0 - 40 °C
Pokaż wszystkie parametry (59)

Konstrukcja

Układ
Rackmount/Tower
Kolor produktu
Czarny
Materiał obudowy
Stal
Diody LED
Zasilanie, Wymiana baterii

Funkcje

Topologia UPS
Podwójnej konwersji (online)
Maksymalna możliwa do konfiguracji moc
6 kVA
Moc rzeczywista
5400 W
Pojemność stelaża
8U
Przebieg falowy
Sinus
Napięcie operacyjne wejścia (minimalne)
120 V
Napięcie operacyjne wejścia (maksymalne)
280 V
Częstotliwość danych wejściowych
40 - 70 Hz
Napięcie operacyjne wyjścia (minimalne)
200 V
Napięcie operacyjne wyjścia (maksymalne)
240 V
Wartość znamionowa udaru energii
2670 J
Współczynnik mocy wejściowej
0,99
Współczynnik szczytu
3:1
Poziom THD prądu wyjściowego
5%
EMI/RFI filtry hałasu
Tak
Ochrona przed nagłym wzrostem napięcia
Tak
Funkcje ochrony przed przepięciami
Sieć, Telefon
Słyszalny alarm
Tak
Tryby alarmu dźwiękowego
Alarm kiedy pracuje na baterii, Alarm niskiego stanu akumulatora, Alarm przeciążenia, Wymiana baterii

Waga i rozmiary

Szerokość produktu
433 mm
Głębokość produktu
820 mm
Wysokość produktu
352 mm
Waga produktu
104,5 kg

Certyfikaty

Certyfikaty zgodności
RoHS

Zawartość opakowania

Przewody
Seryjny, Kabel USB

Safety regulation & standards

Bezpieczeństwo
UL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A

Zrównoważony rozwój

Certyfikat środowiskowy (zrównoważonego rozwoju)
ENERGY STAR

Warunki pracy

Zakres temperatur (eksploatacja)
0 - 40 °C
Zakres temperatur (przechowywanie)
-15 - 45 °C
Zakres wilgotności względnej
0 - 90%
Dopuszczalna wilgotność względna
0 - 95%
Dopuszczalna wysokość podczas eksploatacji (n.p.m.)
0 - 3000 m
Dopuszczalna wysokość (n.p.m.)
0 - 15000 m

Wyświetlacz

Typ wyświetlacza
LCD

Bateria

Technologia baterii
Ołowiany (VRLA)
Pojemność baterii
7 Ah
Typowy czas podtrzymania przy pełnym obciążeniu
5 min
Typowy czas podtrzymania przy połowie obciążenia
15 min
Czas ładowania
4 h
Akumulatory wymieniane podczas pracy
Tak
Kasetka na zapasowe baterie
RB1270X20

Moc

Liczba baterii
20
Funkcje ochrony zasilania
Bezpiecznik wejściowy, Przeciążenie, Krótkie spięcie

Porty i interfejsy

Typy wyjść AC
Terminal, NEMA 5–20R, NEMA L6-20R, NEMA L6-30R
Ilość gniazd sieciowych
13 x gniazdo sieciowe
Port USB
Tak
Interfejs szeregowy
Tak
Porty modemu rj-11
2
Złącze Emergency Power Off (EPO)
Tak

Wydajność

Współczynnik mocy
0,9
Poziom hałasu
55 dB

Dane opakowania

Szerokość opakowania
620 mm
Głębokość opakowania
1120 mm
Wysokość opakowania
1028 mm
Waga wraz z opakowaniem
194,5 kg

Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.

Historia cen (90 dni, najlepsza cena dnia)

Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.

Alternatywne modele