CyberPower OL10KRTHW uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 10000 W 1 AC outlet(s)

CyberPower OL10KRTHW uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 10000 W 1 AC outlet(s)

CyberPowerZasilacze UPSModel OL10KRTHW
  • Układ: Rackmount/Tower
  • Kolor produktu: Czarny
  • Topologia UPS: Podwójnej konwersji (online)
  • Maksymalna możliwa do konfiguracji moc: 10 kVA
  • Moc rzeczywista: 10000 W
  • Dołączone śruby

Wszystkie parametry (70)Strona produktu na cyberpowersystems.com ↗

Gdzie kupić

Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:

Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej

O produkcie

The CyberPower Smart App Online OL10KRTHW is a 6U rackmount or tower UPS with double-conversion topology and maintenance bypass switch. It provides sine wave output to multiple types of critical IT infrastructure requiring, seamless power protection. Generator-compatible, the OL10KRTHW delivers consistent 200-240 V power with zero transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected. The maintenance bypass switch allows for the UPS power module to be hot-swapped for service or replacement without cutting power to the connected equipment.

The OL10KRTHW features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable). Smart battery management charging technology increases battery life by up to 50%. Fast charge technology helps replenish battery charge from 0-90% in four hours regardless of the number of extended battery modules (EBM) connected. The energy-saving GreenPower UPS ECO Mode allows the UPS to reach up to 97% efficiency to reduce power consumption and thermal dissipation.

This UPS can use the BP240VL3U01 Extended Battery Module for more runtime. The OL10KRTHW comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee.

Double-Conversion Topology

Provides consistent, clean, and nearly perfect sine wave output power, regardless of the condition of input power. UPS systems with this technology operate on isolated DC power 100% of the time, and have a zero-transfer time because they electronically switch to battery (vs. using relays which can take 4-12 ms to switch). Double-Conversion UPS systems are designed for high-availability applications, precise output voltage regulation (±2%), generator set compatibility, environments with poor power quality, and other sensitive electronic equipment.

Sine Wave Output

Maintenance Bypass Switch

Provides users the ability to service or replace the UPS without powering down the connected equipment. A patented interlock bracket enables the UPS to automatically switch to internal bypass mode, making the hot-swap process easier and quicker to complete.

Removable LCD Control Panel

Panel displays 24 UPS status readings and allows configuration of 27 operation settings. The onboard Event Log will record and display the five most recent UPS system events. The LCD control panel can be removed and mounted in a more convenient location up to ten feet away from the UPS (with optional DB-26 cable). Users can manage, setup, and control various operation settings. Users can scroll through multiple UPS status readings, and can run select UPS diagnostic tests.

Multiple Language Options

The LCD control panel can be configured to English, Spanish, French, or German for use in multiple countries.

Extended Battery Module (EBM)

Add runtime by connecting more EBMs. The Smart App Online series of UPS systems allow for up to ten EBMs to be connected in a daisy-chain.

Fast Charge Technology

Enables Smart App Online UPS systems with multiple EBMs to charge batteries from 0-90% capacity in four hours. This is possible thanks to the built-in charger in each EBM.

Smart Battery Management (SBM)

Extends the service life of Smart App Online UPS batteries and reduces excessive heat during charge cycles by using a three-stage charging process. The first stage charges the battery to full capacity. The second stage enters float mode, and the third stage turns the charger off to allow the batteries to naturally discharge (rest) for up to 27 days or until they reach a low-voltage set point. SBM continuously monitors the UPS to restart the charge cycle as needed, ensuring that runtimes are maintained.

GreenPower UPS ECO Mode

Improves UPS efficiency up to 97% to reduce electrical and cooling costs.

Hot-Swappable Batteries

Eliminate downtime related to UPS maintenance for continuous power availability.

Generator Compatible

Mode of operation in which the UPS disregards rapid changes in input frequency like those found in the output waveform of some generator sets. This allows the UPS to continue to operate in normal Online Mode vs. switching to Battery Mode when the power source is a generator set.

Converter Mode

Provides the ability to set the UPS output frequency (50 Hz or 60 Hz), regardless of the input frequency. This is beneficial where the connected equipment must operate on a different frequency than provided by local electric utility.

Local and Remote Management

Monitor and manage the UPS system locally via USB or serial connection, or remotely via the pre-installed RMCARD205 network card. Access UPS status, configuration settings, event logs and status records, setup email notifications, and more.

Rack or Tower Installation

All the hardware accessories to rack mount the UPS in a standard 19” rack, or install as a tower unit, is included at no extra cost.

PowerPanel Business Edition Software

Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality. Free software download available here.

Three-Year Warranty

CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date.

Connected Equipment Guarantee

CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

Dokumenty

Specyfikacja

Najważniejsze parametry

Układ
Rackmount/Tower
Kolor produktu
Czarny
Topologia UPS
Podwójnej konwersji (online)
Maksymalna możliwa do konfiguracji moc
10 kVA
Moc rzeczywista
10000 W
Dołączone śruby
Tak
Certyfikaty zgodności
RoHS
Zestaw do montażu haków
Tak
Podręcznik użytkownika
Tak
Bezpieczeństwo
UL 1778 5th Ed., CSA C22.2 NO.107.3-05, FCC 15 A
Pokaż wszystkie parametry (70)

Konstrukcja

Układ
Rackmount/Tower
Kolor produktu
Czarny
Materiał obudowy
Stal

Funkcje

Topologia UPS
Podwójnej konwersji (online)
Maksymalna możliwa do konfiguracji moc
10 kVA
Moc rzeczywista
10000 W
Pojemność stelaża
6U
Przebieg falowy
Sinus
Napięcie operacyjne wejścia (minimalne)
120 V
Napięcie operacyjne wejścia (maksymalne)
280 V
Częstotliwość danych wejściowych
40 - 70 Hz
Napięcie operacyjne wyjścia (minimalne)
200 V
Napięcie operacyjne wyjścia (maksymalne)
240 V
Frekwencja wyjściowa
50/60 Hz
Wartość znamionowa udaru energii
2430 J
Czas transferu (Tryb Linii do Trybu Baterii)
0 ms
Wydajność (tryb ECO)
97%
Współczynnik mocy wejściowej
0,99
Współczynnik mocy wyjściowej
1
Współczynnik szczytu
3:1
Zdolność przeciążeniowa (1 minuta)
125%
Zdolność przeciążeniowa (10 sekund)
150%
Całkowite zniekształcenie harmoniczne (THD) (obciążenie liniowe)
3%
Całkowite zniekształcenie harmoniczne (THD) (obciążenie nieliniowe)
5%
EMI/RFI filtry hałasu
Tak
Ochrona przed nagłym wzrostem napięcia
Tak
Funkcje ochrony przed przepięciami
Sieć, Telefon

Zawartość opakowania

Dołączone śruby
Tak
Zestaw do montażu haków
Tak
Podręcznik użytkownika
Tak

Waga i rozmiary

Szerokość produktu
433 mm
Głębokość produktu
820 mm
Wysokość produktu
264 mm
Waga produktu
104,5 kg

Certyfikaty

Certyfikaty zgodności
RoHS

Safety regulation & standards

Bezpieczeństwo
UL 1778 5th Ed., CSA C22.2 NO.107.3-05, FCC 15 A

Warunki pracy

Zakres temperatur (eksploatacja)
0 - 40 °C
Zakres temperatur (przechowywanie)
-20 - 45 °C
Zakres wilgotności względnej
0 - 90%
Dopuszczalna wilgotność względna
0 - 95%
Dopuszczalna wysokość podczas eksploatacji (n.p.m.)
0 - 3000 m
Dopuszczalna wysokość (n.p.m.)
0 - 15000 m

Wyświetlacz

Typ wyświetlacza
LCD

Bateria

Technologia baterii
Ołowiany (VRLA)
Pojemność baterii
9 Ah
Napięcie baterii
12 V
Typowy czas podtrzymania przy pełnym obciążeniu
3,6 min
Typowy czas podtrzymania przy połowie obciążenia
10 min
Battery recharge time (90%)
5 h
Akumulatory wymieniane podczas pracy
Tak
Zimny start
Tak
Kasetka na zapasowe baterie
RB1290X10

Moc

Liczba baterii
20
Funkcje ochrony zasilania
Przeciążenie, Krótkie spięcie

Porty i interfejsy

Ilość gniazd sieciowych
1 x gniazdo sieciowe
Port USB
Tak
Liczba portów USB 2.0
1
Typ portu USB
USB Typu B
Interfejs szeregowy
Tak
Interfejs SCSI
RS-232
Port RS-232
1
Porty modemu rj-11
2
Ilość portów Ethernet LAN (RJ-45)
2

Cechy zarządzania

Tryb ECO
Tak

Wydajność

Poziom hałasu
65 dB

Dane opakowania

Gumowe nóżki
Tak
Szerokość opakowania
620 mm
Głębokość opakowania
1120 mm
Wysokość opakowania
650 mm
Waga wraz z opakowaniem
131,2 kg

Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.

Historia cen (90 dni, najlepsza cena dnia)

Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.

Alternatywne modele