CyberPower MBP20A6 power distribution unit (PDU) 6 AC outlet(s) 1U Black

CyberPower MBP20A6 power distribution unit (PDU) 6 AC outlet(s) 1U Black

CyberPowerRozdzielacze zasilania PDUModel MBP20A6
  • Ilość gniazd sieciowych: 6 x gniazdo sieciowe
  • Zakres temperatur (eksploatacja): 0 - 40 °C
  • Zakres wilgotności względnej: 0 - 90%
  • Certyfikaty zgodności: RoHS
  • Certyfikaty: UL60950_1, cUL
  • Wartość nominalna napięcia wejściowego: 100 - 120 V

Wszystkie parametry (18)Strona produktu na cyberpowersystems.com ↗

Gdzie kupić

Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:

Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej

O produkcie

The CyberPower MBP20A6, a 6-outlet (rear), 1U Maintenance Bypass Power Distribution Unit (MBP PDU), provides 100-120 VAC 20A output (derated to 16A) to 6 NEMA 5-20R receptacles. Designed for datacenters and other electrically demanding applications, the MBP20A6 allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS.

A 6-foot AC cord connects to utility power; a 3.3-foot AC cord connects to the output power of the UPS. The UPS draws input power from the MBP20A6 through a dedicated NEMA 5-20R separate from the outlets for connected devices. When the switch on the front of the MBP20A6 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active.

Rugged, industrial-grade metal housing protects the MBP20A6. With a 1U form factor, this PDU can be mounted in a standard server rack. Its mounting hardware also enables it to be connected to a UPS for tower configurations. The MBP20A6 is UL and RoHS compliant. A three-year limited warranty covers the PDU for three years and connected equipment for as long as you own the product.

Power Distribution

Delivers AC power to servers, equipment, and connected devices via a power distribution unit.

Maintenance Bypass

Qualified personnel can use the bypass feature to disconnect the PDU from the UPS without disrupting power to connected equipment. This feature allows connected equipment to operate seamlessly during maintenance periods, battery replacement, or UPS installation.

Manual Bypass Switch

When the Manual Bypass Switch is turned to Normal, connected equipment is supplied by UPS output. When the Manual Bypass Switch is turned to Bypass, connected equipment is supplied by utility power.

Network-Grade Plugs and Outlets

Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.

1U Form Factor & Mounting Hardware

The 1U form factor is made to be mounted in a standard server rack. Mounting hardware allows the PDU to be connected to a UPS for tower configurations.

Durable Metal Housing

Protects internal components and resists damage from impact or abrasions within challenging industrial environments. Also extends the life of the product.

Three-Year Limited Warranty

Covers defects in materials and workmanship in the product under normal use and conditions. See warranty for details.

Specyfikacja

Porty i interfejsy

Ilość gniazd sieciowych
6 x gniazdo sieciowe
Wtyczka
NEMA 5–20P
Typy wyjść AC
NEMA 5–20R

Waga i rozmiary

Szerokość produktu
431,8 mm
Głębokość produktu
76,2 mm
Wysokość produktu
50,8 mm
Waga produktu
2 kg

Warunki pracy

Zakres temperatur (eksploatacja)
0 - 40 °C
Zakres wilgotności względnej
0 - 90%

Certyfikaty

Certyfikaty zgodności
RoHS
Certyfikaty
UL60950_1, cUL

Moc

Wartość nominalna napięcia wejściowego
100 - 120 V
Maksymalne natężenie prądu
20 A

Pozostałe funkcje

Wartość nominalna napięcia wyjściowego
120 V

Funkcje

Długość kabla
1,82 m
Pojemność stelaża
1U

Konstrukcja

Materiał obudowy
Stal
Kolor produktu
Czarny