APC SUVTP10KF1B4S uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA 8000 W 1 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 10 kVA
- Output power: 8000 W
- Battery type: VRLA
Wszystkie parametry (31)Strona produktu na ops-ecat.schneider-electric.com ↗
Gdzie kupić
Nie śledzimy jeszcze cen tego produktu. Sprawdź aktualne ceny bezpośrednio w sklepach:
Możemy otrzymać prowizję, gdy kupujesz przez linki na tej stronie — bez dodatkowych kosztów dla Ciebie. Dowiedz się więcej
Specyfikacja
Najważniejsze parametry
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 8000 W
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- VRLA
- InterfaceInterface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit/s (USB 1: 12 Mbit/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2.
- DB-9 RS-232, SmartSlot
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -50 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Pokaż wszystkie parametry (31)Pokaż tylko najważniejsze parametry
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 8000 W
- InterfaceInterface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit/s (USB 1: 12 Mbit/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2.
- DB-9 RS-232, SmartSlot
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 165 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 240 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 208 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Power
- Battery typeDescription of battery supplied with the product, such battery form factor (e.g. AA/AAA).
- VRLA
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 523 mm
- DepthThe distance from the front to the back of something.
- 813 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1499 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 506.8 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -50 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 999.9 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 5 h
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 1 AC outlet(s)
- Serial ports quantityThe number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial po…
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 54 dB
Packaging data
- Package weightWeight of the packaged product.
- 537.7 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Udostępniane „tak jak są”, bez gwarancji — przed zakupem sprawdź szczegóły w sklepie.
Historia cen (90 dni, najlepsza cena dnia)
Wciąż zbieramy historię cen tego produktu — zajrzyj wkrótce.
Alternatywne modele

APC MGE Galaxy 5500 60KVA 400V Integrated Pa uninterruptible power supply (UPS) Double-conversion (Online)
54000 W 1 AC outlet(s)
Specyfikacja i gdzie kupić

APC SMC1500I + Service Bundle 3 uninterruptible power supply (UPS) 1.5 kVA
900 W 8 AC outlet(s)
Specyfikacja i gdzie kupić

APC G55TUPSU40HS uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
36000 W 1 AC outlet(s)
Specyfikacja i gdzie kupić

APC SMC1000I + Service Bundle 3 uninterruptible power supply (UPS) 1 kVA
600 W 8 AC outlet(s)
Specyfikacja i gdzie kupić

APC SUA1500IX38 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
980 W
Specyfikacja i gdzie kupić

APC Smart-UPS On-Line SRT10KRMXLI - 10kW/VA, 6x C13 + 4x C19 + hardwire 1 phase output, rack mountable, Embedded NMC
Specyfikacja i gdzie kupić