
Vertiv Avocent PM3012V power distribution unit (PDU) 20 AC outlet(s) 0U Black
- AC outlets quantity: 20 AC outlet(s)
- Operating temperature (T-T): 10 - 45 °C
- Storage temperature (T-T): -40 - 65 °C
- Nominal input voltage: 100-240 V
- AC input frequency: 50 - 60 Hz
- Maximum current: 16 A
All 17 specificationsProduct page at emersonnetworkpower.com ↗
Model numbers
- PM3012V-201
- PM3012V-202
- PM3012V-203
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Avocent Power Management Distribution Units (PM PDUs)
include single-phase and three-phase models that support strip-level metering, outlet-level metering or outlet-level metering and switching. This advanced family of rack PDUs includes horizontal and vertical models for a variety of rack configurations in branch and remote offices. With the ability to support up to 22 kW and models that include support for C19 outlets, the Avocent PM PDUs are well positioned to support the high rack density found in organizations today.
The PM PDUs include a LED display and a built-in browser interface for local and remote access to real-time data. The metering features, along with the capability to set custom thresholds, allow companies to optimize their electrical infrastructure, without the risk of downtime due to overloaded circuits.
The PM 1000 PDUs enable companies of all sizes to accurately measure the current, voltage and power for the entire strip and the circuits within. The PM 2000 and PM 3000 PDUs take this a step further to support outlet-level metering and switching capability (PM 3000 PDUs only) to provide data center professionals the tools they need to monitor, measure, reduce and manage the growing power consumption costs of IT equipment.
All of these PDUs include advanced features that consist of a built-in network port for access to the browser interface, daisy chain ports for easy installation and expansion and support for external, environmental sensors.
For a total solution, the PM 1000/2000/3000 devices can be used with other Avocent appliances for integrated IP access to the attached equipment, along with power measurement and/or control for improved remote management.
When used with the Avocent DSView management software, users gain secure access and control across multiple locations. The optional Avocent DSView Power Manager plug-in allows real-time and historical reporting of capacity, consumption and cost across single PDUs or groups of PDUs.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 20 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 81 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1321 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4.99 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 10 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -40 - 65 °C
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 100-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Humidity, Temperature
Features
- Cable lengthHow long the cable is.
- 3.048 m
- Rack capacityThe spase that device fill in rack.
- 0U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Vertiv Avocent PM1011H power distribution unit (PDU) 10 AC outlet(s) Black

Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V 3x16A, outputs
(48)C13

Vertiv Avocent PM1014V power distribution unit (PDU) 20 AC outlet(s) Black

Vertiv Avocent PM1013V power distribution unit (PDU) 10 AC outlet(s) Black

Vertiv Avocent PM1009H power distribution unit (PDU) 10 AC outlet(s) Black
