Vertiv Liebert MP2-210K power distribution unit (PDU) 4 AC outlet(s) 2U Black
- AC outlets quantity: 4 AC outlet(s)
- Operating temperature (T-T): 0 - 40 °C
- Storage temperature (T-T): -20 - 60 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
- Nominal input voltage: 230 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Liebert MicroPOD maintenance bypass and power output distribution switch allows you to manually transfer the connected equipment to utility power via a maintenance bypass switch,
permitting scheduled maintenance or UPS replacement without discontinuing power to the critical load. Transferring back to UPS power is just as easy — simply turn the switch to the indicated
position and the load is protected by the UPS. Available in plug-andplay or hardwired options at 120V or 208V rating, units include brackets for rack mounting in any direction.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C13 coupler
- AC outlet typesThe type of outlet for AC electricity.
- C14 coupler
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 10 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 2U
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 432 mm
- Package depthThe distance from the front to the back of the packaging.
- 89 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 89 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Vertiv MP2-220L power distribution unit (PDU) 4 AC outlet(s) 2U Black

Vertiv Avocent PM2011V power distribution unit (PDU) 20 AC outlet(s) Black

Vertiv Avocent PM1013V power distribution unit (PDU) 10 AC outlet(s) Black

Vertiv Avocent PM1010H power distribution unit (PDU) 10 AC outlet(s) Black

Vertiv Knürr DIS Rack PDU, TripplePower, 0U, input IEC 60309 230/400V 3x16A, outputs
(48)C13