Vertiv Liebert GXT3 On-Line RT 10000VA uninterruptible power supply (UPS) 10 kVA 9000 W
- Form factor: Rackmount/Tower
- Product colour: Black
- Output power capacity: 10 kVA
- Output power: 9000 W
- Number of phases: 1
- Safety: UL 1778, c-UL
All 24 specificationsProduct page at emersonnetworkpower.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Liebert GXT3 5 kVA to 10 kVA uninterruptible power supply (UPS) systems provide true on-line protection in the smallest cabinets in their capacity range. These data center power systems offer internal batteries, unlimited extended external batteries, and internal bypass capability, resulting in continuous uptime for the connected equipment. Multiple data center power output configurations allow quick connection of protected loads.
Designed for rack-mount or tower modes, the Liebert GXT3 uninterruptible power system is available in 5kVA and 6kVA, 4U models; and 8kVA and 10kVA, 6U models. All models are available with output of 120/208V. Please note that the internal batteries for the Liebert GXT3 5kVa to 10kVA UPS must be ordered separately, and will ship separately. Depending upon the model you select, there may also be a separate POD required.
Specifications
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- Rack capacityThe spase that device fill in rack.
- 6U
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 120 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 208 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 100 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 127 V
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2%
Power
- Number of phasesThe total number of power stages or phases used to regulate and distribute electrical current to the components.
- 1
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 430 mm
- DepthThe distance from the front to the back of something.
- 672 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 261 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 35.5 kg
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- UL 1778, c-UL
Sustainability
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 50 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Ports & interfaces
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models
Vertiv Liebert DUST FILTER KIT FOR NXC 30KVA AND 40KVA uninterruptible power supply (UPS)

Vertiv Liebert APM uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA

Vertiv Liebert APS 16-Bay Frame 1-Phase 5kVA with 2 internal Battery Strings 8-10Y

Vertiv Liebert APM uninterruptible power supply (UPS) Double-conversion (Online) 60 kVA

Vertiv Liebert itON UPS 1500VA/900W 230V Line Interactive Tower AVR, VRLA Battery,3Schuko + 3IEC 320-C13 (LI32141CT20)