Techly IUPS-SRA16-A3 power distribution unit (PDU) 9 AC outlet(s) 1U Black
- AC outlets quantity: 9 AC outlet(s)
- Operating relative humidity (H-H): 0 - 90%
- Operating temperature (T-T): 0 - 40 °F
- Compliance certificates: CE
- Nominal input voltage: 100 - 280 V
- AC input frequency: 40/70 Hz
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Automatic redundant system for UPS
Redundant system of two ups with single power rack 19 "- 1U - For ups 3-4 KVA - 1 16A power cable - 4 10 / 16A output cables - 1 IEC 16A male connector
Maximum input current 16A.
Double load power with automatic redundancy.
In case of failure of an UPS, priority power (UPS master) automatically switches to secondary power (slave UPS).
It is possible to connect only one UPS (master) and a direct secondary network (slave) to ensure continuity of supply to the connected equipment.
Versatile installation that adapts to various work environments (19 "rack or wall mounting).
Technical data: IEC - 16A
- Entrance:
- Input Voltage 208/220/230/240 VAC
- Acceptable input voltage 100 - 280 VAC
- Input frequency 40-70 Hz
- Rated input current 16 A
- Exit
- Output voltage 208/220/230/240 VAC
- Maximum output current 16 A
- Switching time
- Master UPS -> Slave UPS 10 ms. max.
- Slave UPS -> Master UPS 4 ms. max.
- Connections:
- 1 x IEC-C20 network connection (16A male)
- UPS inputs 2 x IEC-C19 (16A female)
- UPS outputs 2 x IEC-C20 (16A male)
- 4 x IEC-C13 loads (10A female) and 1 x IEC-C19 (16A female)
- Indicators:
- Main LED Power LED Green light
- UPS UPS output light LED Green light
- LED Slave UPS output orange light
- Physical characteristics
- Dimensions (H x W x D) / Weight: 44 mm x 448 x 10 cm / 1.8 kg
- Operating temperature 0-40 ° C
- Relative humidity 0-90% (non-condensed)
- Accessories Included:
- 1 x 16A power cable, 4 x 16A output cable, 1 x IEC-16A male connector
The package includes
- Redundant system for ups 3-4 KVA Rack 19"
- 1 x 16A power cord,
- 4 x 16A output cable,
- 1 x male IEC-16A connector
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 9 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler, C20 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 448 mm
- DepthThe distance from the front to the back of something.
- 44 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 10 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.8 kg
Operational conditions
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °F
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 100 - 280 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 40/70 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Housing materialWhat the casing of the product is made of.
- Metal, Plastic
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 1U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Techly IUPS-SRA16-A2 power distribution unit (PDU) 9 AC outlet(s) 1U Black

Techly I-CASE STRIP-17P power distribution unit (PDU) 7 AC outlet(s) 1.5U Black, Silver

Techly Rack 19" Power Strip 6 Outlets 1U Italian Plug

Techly I-CASE STRIP-18A power distribution unit (PDU) 8 AC outlet(s) 1.5U Black

Techly Rack 19" Power Strip 8 Outlet Italian Plug 1U Cable 3m