Samsung AM080FXWANR Air conditioner outdoor unit White
- Type: Air conditioner outdoor unit
- Product colour: White
- Air conditioner functions: Cooling, Heating
- Inverter technology
- Outdoor unit noise level: 48 dB
- Outdoor unit sound power level: 70 dB
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Samsung DVM S Water
Water Cooling
The DVM S WATER is a cooling & heating system for buildings that uses water as its heat source, with connections to cooling towers and boilers, or alternatively to geothermal source. Samsung water cooled VRF provides stable and reliable performance with minimal effect from ambient conditions. It offers versatility with the ability to connect multiple indoor units and a wide variety of indoor types to choose from. Samsung DVM S Water source VRF units area a great option for retro-fit or new constructions.
High efficiency
Dual Inverter Compressors
The DVM S WATER air conditioning system provides efficient and powerful performance. Its innovative Dual Inverter Compressor, with a high efficiency Vapor Injection System, ensures powerful, rapid cooling and heating.
Flexible installation almost anywhere
Flexible Installation
The DVM S WATER can be install with great flexibility; It has an allowable piping length of up to 170 meters between the outdoor and indoor units, and a height of separation of up to 50 meters.
Precise Control
Independently Cool & Heat
Heat Recovery systems add the capability to heat and cool separate zones simultaneously, making DVM S WATER an excellent choice.
Optimum water flow controller
Built-in Water Flow logic
The DVM S WATER’s built-in Water Flow Controller helps to control the amount of water required to cool and heat the outdoor unit, it determines the water flow required based on the internal temperature of the spaces, hence assisting with water pump power efficiency.
The outside of your building stays neat
Louver-less installation
The DVM S WATER can easily be install into plant spaces, as the outdoor unit heat is remove by water, there is little impact on the aesthetics of its architectural design.
Quiet comfort
Minimal noise level
The DVM S WATER outdoor unit has a low operating noise level, as it uses a water-cooled Plate Heat Exchanger for system heat rejection, there is no outdoor fan, reducing the sound impact on your building’s working environment.
Documents
- ManualUser manual ↗
- DocumentDisassembly ↗
- DocumentEcodesign ↗
Specifications
Key specifications
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 48 dB
- Outdoor unit sound power levelThe total acoustic energy emitted by the external component of the system, measured in decibels (e.g. 55 dB).
- 70 dB
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 77 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 54.5 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 100 cm
Show all 35 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 5.83
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 6.12
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 22400 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 25200 W
- Cooling capacity (nominal)The amount of heat the unit can remove from an indoor space per hour, measured in British Thermal Units per hour (BTU/h) or kilowatts (kW).
- 76400 BTU/h
- Heating capacity (nominal)The amount of heat the unit can produce under standard operating conditions, measured in watts or British Thermal Units per hour (e.g. 3500 W or 12000 BTU/h).
- 86000 BTU/h
- Refrigerating medium weightThe total mass of the coolant gas used in the cooling system, measured in grams or kilograms.
- 5.5 kg
- Compressor typeThe technology used by the pump to compress the refrigerant and circulate it through the system (e.g. Inverter, Linear, or Rotary).
- Twin Rotary
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 170 m
- Gas hose diameterThe internal width of the gas connection, typically measured in millimetres.
- 1.91 cm
- Liquid hose diameterThe internal diameter of the line used for the liquid refrigerant, typically measured in millimetres or inches.
- 9.52 mm
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- 10 - 45 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- 10 - 45 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R410A
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 48 dB
- Outdoor unit sound power levelThe total acoustic energy emitted by the external component of the system, measured in decibels (e.g. 55 dB).
- 70 dB
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 77 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 54.5 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 100 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 160 kg
- Outdoor unit package widthThe width of the packaging for the outdoor unit of the split-system air conditioner, measured in millimeters.
- 84 cm
- Outdoor unit package depthThe depth of the packaging for the outdoor unit of the split-system air conditioner, measured in millimeters.
- 62 cm
- Outdoor unit package heightThe total height of the outdoor unit including its shipping packaging, measured in millimeters.
- 120 cm
- Outdoor unit package weightThe total weight of the outdoor unit including its packaging, measured in g.
- 167 kg
Power
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 3.84 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 4.12 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 380 - 415 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Current (cooling)The amount of electrical current drawn by the unit during the cooling process, measured in amperes (e.g. 4.5 A).
- 6.2 A
- Current (heating)The amount of electrical current consumed by the unit during the heating process, measured in amperes (e.g. 5.2 A).
- 6.6 A
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Samsung AM090FNLDEH Air conditioner indoor unit Brushed steel

Samsung AM140HNMPKH Air conditioner indoor unit Brushed steel

Samsung AM050FXMDEH Air conditioner outdoor unit White

Samsung AM040FXMDGH Air conditioner outdoor unit White

Samsung AM120FXVAGH Air conditioner outdoor unit White