Samsung AC026MN1DKH/EU air conditioner Split system White
- Type: Split system
- Product colour: White
- Air conditioner functions: Cooling, Dehumidifying, Heating
- Outdoor unit noise level: 52 dB
- Indoor unit type: Cassette
- Indoor unit noise level (low speed): 23 dB
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Documents
- ManualUser manual ↗
Specifications
Key specifications
- TypeCharacteristics of the device.
- Split system
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 52 dB
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Cassette
- Indoor unit noise level (low speed)The sound pressure level emitted by the indoor unit when operating at the lowest fan speed, measured in decibels (dB).
- 23 dB
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 30 dB
- Indoor unit sound power levelThe total acoustic energy emitted by the internal component, measured in decibels (dB).
- 30 dB
- Cooling airflow (indoor unit)The volume of air circulated by the indoor unit during cooling mode, measured in cubic meters per hour (m³/h).
- 360 m³/h
- Heating airflow (indoor unit)The volume of air delivered by the indoor unit during heating mode, typically measured in cubic meters per hour (m³/h).
- 480 m³/h
Show all 48 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Split system
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 5.6
- Seasonal efficiency rating (heating) (SCOP) (Average heating season)The ratio of the total heat energy delivered by the device to the total electrical energy consumed during an entire heating season, based on average climate conditions.
- 3.8
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 2600 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 980 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 3500 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 3300 W
- Heating capacity in watts (min)The minimum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 950 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 4600 W
- Refrigerating medium weightThe total mass of the coolant gas used in the cooling system, measured in grams or kilograms.
- 950 g
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 20 m
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Built-in displayA display which is part of the product, so you do not need to attach another display.
- No
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R410A
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 52 dB
Indoor unit
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Cassette
- Indoor unit noise level (low speed)The sound pressure level emitted by the indoor unit when operating at the lowest fan speed, measured in decibels (dB).
- 23 dB
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 30 dB
- Indoor unit sound power levelThe total acoustic energy emitted by the internal component, measured in decibels (dB).
- 30 dB
- Cooling airflow (indoor unit)The volume of air circulated by the indoor unit during cooling mode, measured in cubic meters per hour (m³/h).
- 360 m³/h
- Heating airflow (indoor unit)The volume of air delivered by the indoor unit during heating mode, typically measured in cubic meters per hour (m³/h).
- 480 m³/h
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 1
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 97 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 41 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 15.5 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 9.5 kg
- Indoor unit package widthThe width of the packaging for the indoor unit of the split-system air conditioner, measured in millimeters.
- 118 cm
- Indoor unit package depthThe depth of the packaging for the indoor unit of the split-system air conditioner, measured in millimeters.
- 46 cm
- Indoor unit package heightThe vertical dimension of the packaging for the indoor unit of the split-system air conditioner, measured in millimeters.
- 2.5 cm
- Indoor unit package weightThe total weight of the indoor unit including its packaging, measured in g.
- 3.1 kg
Power
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
- Annual energy consumption (cooling)This is a measure of the energy used in a year by the air conditioning (AC) when it is used to cool air.
- 62 kWh
- Annual energy consumption (heating) (Warmer heating season)The total amount of electricity used for heating purposes over a year based on a milder climate profile, measured in kilowatt-hours.
- 4 kWh
- Power consumption (cooling) (min)The minimum amount of electrical power required to operate the unit in cooling mode, measured in Watts.
- 250 W
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 1120 W
- Power consumption (heating) (min)The minimum amount of electrical power required by the unit to operate in heating mode, measured in Watts.
- 210 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 1300 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 220-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 5.4 A
- Design load (cooling)The maximum cooling capacity the unit is designed to provide under standard operating conditions, measured in kW.
- 1.2 kW
- Design load (heating) (Warmer heating season)The thermal output the unit provides during the heating cycle under warmer seasonal conditions, measured in kW.
- 1.45 kW
- Design load (heating) (Average heating season)The average amount of thermal energy required to maintain the desired indoor temperature during the heating season, measured in kilowatts.
- 0.72 kW
- Design load (heating) (Colder heating season)The thermal output the unit is designed to provide during the coldest part of the heating season, measured in kW.
- 0.96 kW
Performance
- Thermostat rangeThe minimum and maximum temperature limits that can be set or maintained by the device, measured in °C.
- -20 - 50 °C
- Remotely operatedThe device can be controlled by remote control, which is a device that controls an apparatus by means of radio or infrared signals.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Samsung AC026MNADKH/EU air conditioner Split system White
Specs & where to buy

Samsung AC035MNADKH/EU air conditioner Split system White
Specs & where to buy

Samsung AR24NSFSCWK Split system White
Specs & where to buy

Samsung AC052MNADKH/EU air conditioner Split system White
Specs & where to buy

Samsung AR09NSFSCWK Split system White
Specs & where to buy

Samsung AC071MNADKH/EU air conditioner Split system White
Specs & where to buy