Nilox Premium Line Interactive Sinewave 3.000 uninterruptible power supply (UPS) Line-Interactive 3 kVA 2100 W 4 AC outlet(s)
- Form factor: Mini Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 3 kVA
- Output power: 2100 W
- Certification: CE
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2100 W
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Housing materialWhat the casing of the product is made of.
- Metal, Plastic
Show all 42 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Mini Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Housing materialWhat the casing of the product is made of.
- Metal, Plastic
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2100 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 220 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 230 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 230 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 145 mm
- DepthThe distance from the front to the back of something.
- 380 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 200 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 17 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 2 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Number of battery cellsThe total quantity of individual battery cells used to power the device, including configurations with primary and backup cells (e.g., 1+2).
- 2
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 5 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 10 min
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 8 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C14 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 2
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.7
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 45 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 230 mm
- Package depthThe distance from the front to the back of the packaging.
- 495 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 285 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Nilox UPS PREMIUM ONLINE PRO 1000 VA uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA
700 W 1 AC outlet(s)
Specs & where to buy

Nilox Premium Line Interactive Sinewave 2.000 uninterruptible power supply (UPS) Line-Interactive 2 kVA
1400 W 4 AC outlet(s)
Specs & where to buy

Nilox UPS PREMIUM ONLINE PRO 3000 VA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2100 W 1 AC outlet(s)
Specs & where to buy

Nilox NXGCLI12001X7V2 uninterruptible power supply (UPS) Line-Interactive 1.2 kVA
840 W 2 AC outlet(s)
Specs & where to buy

Nilox UPS PREMIUM LINE INT. 2600VA uninterruptible power supply (UPS) Line-Interactive 2.6 kVA
1820 W
Specs & where to buy

Nilox NXGCLI20002X9V2 uninterruptible power supply (UPS) Line-Interactive 2 kVA
1400 W
Specs & where to buy