NETGEAR GS724T-600NAS network switch Managed L2+/L3 Gigabit Ethernet (10/100/1000) 1U Blue, Grey
- Rack mounting
- MAC address table: 16000 entries
- Basic switching RJ-45 Ethernet ports quantity: 24
- Basic switching RJ-45 Ethernet ports type: Gigabit Ethernet (10/100/1000)
- Switch type: Managed
- Operating temperature (T-T): 0 - 45 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
NETGEAR GS724T Smart Cloud Switch offers powerful L2 and L2+/Layer 3 Lite features and enhanced performance and usability. Manage remotely with Insight Cloud Management
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Rack mountingThe type of mounting that can position devices in a shelving system (rack).
- Yes
- MAC address tableThe MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.
- 16000 entries
- Basic switching RJ-45 Ethernet ports quantityThe number of basic switching RJ-45 Ethernet ports (sockets).
- 24
- Basic switching RJ-45 Ethernet ports typeThe type/category of basic switching RJ-45 Ethernet ports (sockets).
- Gigabit Ethernet (10/100/1000)
- Switch typeWhat switch device has, managed or unmanaged.
- Managed
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Show all 57 specificationsShow key specifications only
Power over Ethernet (PoE)
- Power over Ethernet (PoE)The device supports Power over Ethernet (PoE), which is one of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras.
- No
Design
- Rack mountingThe type of mounting that can position devices in a shelving system (rack).
- Yes
- Form factorThe shape or design of the product.
- 1U
- Product colourThe colour e.g. red, blue, green, black, white.
- Blue, Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Activity, Link
- Number of fansThe quantity of fans (apparatus with rotating blades that creates a current of air for cooling or ventilation).
- 0 fan(s)
Data transmission
- MAC address tableThe MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.
- 16000 entries
- Switching capacityThe data transfer capacity of the switch per second.
- 52 Gbit/s
- Number of queuesThe total number of hardware buffers or priority queues available for managing data traffic flow.
- 8
- Number of static routesThe maximum number of fixed network paths that can be manually configured in the routing table.
- 32
- Jumbo framesIndicates the support for Ethernet frames larger than the standard 1500 bytes to increase data transfer efficiency (e.g. 9000 bytes).
- 9000
- Packet buffer memoryThe amount of memory available in the network switch to temporarily store data packets during congestion, typically measured in megabytes (MB) or kilobytes (KB).
- 2 MB
Ports & interfaces
- Basic switching RJ-45 Ethernet ports quantityThe number of basic switching RJ-45 Ethernet ports (sockets).
- 24
- Basic switching RJ-45 Ethernet ports typeThe type/category of basic switching RJ-45 Ethernet ports (sockets).
- Gigabit Ethernet (10/100/1000)
- SFP module slots quantityThe total number of available slots for inserting Small Form-factor Pluggable (SFP) transceiver modules.
- 2
- Power connectorThe type of electrical interface used to provide power to the network switch, such as a C13 socket or a DC-in jack.
- DC-in jack
Management features
- Switch typeWhat switch device has, managed or unmanaged.
- Managed
- Firmware upgradeableIndicates whether the internal software of the device can be updated to a newer version to improve performance or add features.
- Yes
- Switch layerA network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things).
- L2+/L3
- Quality of Service (QoS) supportIndicates whether the device supports Quality of Service (QoS) to prioritize specific network traffic to ensure performance for critical applications.
- Yes
- System event logIndicates whether the device maintains a record of internal system events and status changes for diagnostic purposes.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 328 mm
- DepthThe distance from the front to the back of something.
- 169 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 43 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 1.62 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 3000 m
Power
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 100 - 240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50/60 Hz
- Power consumption (typical)Amount of power consumed by this model, often expressed in watts (W). Typical values that manufacturers give are power consumption when off, standby/suspended mode, typical use, maximum usage.
- 13.5 W
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 0 dB
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- SNMP v1/v2
- Access Control List (ACL)Indicates whether the device supports the definition of rules to filter network traffic and manage access permissions based on specific criteria.
- Yes
- Security algorithmsSecurity algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.
- HTTPS, SSL/TLS
- Web-based managementUsing a website/web application to manage something.
- Yes
Features
- Mean time between failures (MTBF)Statistical model used to indicate product/mechanism reliability; expressed in hours and percentage of duty cycle. This number (in hours) does not indicate the mean time before failure for a single unit/mechanism.
- 1999946 h
- Full duplexA full-duplex system allows communication in both directions, and unlike half-duplex, allows this to happen simultaneously.
- Yes
Multicast features
- Multicast supportIndicates whether the device supports the simultaneous transmission of a single data stream to multiple recipients.
- Yes
- Number of multicast groups filteredThe maximum number of multicast groups that the device can simultaneously filter to manage network traffic flow.
- 512
Security
- DHCP featuresSpecifies the supported Dynamic Host Configuration Protocol (DHCP) options for network configuration, such as DHCP Option 66 for boot server addresses.
- DHCP client, DHCP snooping
- IGMP snoopingIndicates whether the device can optimize multicast traffic by ensuring it is only forwarded to the ports that have requested it.
- Yes
- MAC address filteringSecurity access control method whereby the 48-bit address assigned to each network card is used to determine access to the network. MAC addresses are uniquely assigned to each card, so using MAC filtering on a network permits and denies network access to specific devices through the use of blacklists and whitelists.
- Yes
- SSH/SSL supportIndicates whether the device supports secure remote management via SSH or SSL protocols.
- Yes
Network
- Jumbo frames supportIndicates whether the device supports Ethernet frames with a payload larger than the standard 1500 bytes to increase data transfer efficiency.
- Yes
- Networking standardsThe way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g.
- IEEE 802.1D, IEEE 802.1ab, IEEE 802.1as, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.3ad, IEEE 802.3ae, IEEE 802.3x, IEEE 802.3z
- 10G supportThe product can use Oracle 10G, which is a database management system introduced in 2003.
- Yes
- Port mirroringIndicates whether the network switch can copy traffic from one or more ports to another port for monitoring and analysis purposes.
- Yes
- IP routingIndicates whether the device can forward data packets between different networks by determining the best path to the destination.
- Yes
- Flow control supportIndicates whether the device supports the management of data transmission rates to prevent buffer overflow.
- Yes
- Broadcast storm controlIndicates whether the device can monitor and limit the amount of broadcast traffic to prevent network congestion and potential crashes.
- Yes
- Spanning tree protocolIndicates whether the device supports a network protocol that prevents loops in a bridge network topology.
- Yes
- VLAN supportA Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings, but form one LAN on a logical level.
- Yes
- Number of VLANsThe maximum number of virtual local area networks that can be configured on the device to segment network traffic.
- 256
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

NETGEAR GS305PP Unmanaged Gigabit Ethernet
(10/100/1000) Power over Ethernet (PoE) Black
Specs & where to buy

NETGEAR 24PT GIGABIT SWITCH Unmanaged Gigabit Ethernet
(10/100/1000) Grey
Specs & where to buy

NETGEAR MS308E Unmanaged 2.5G Ethernet
(100/1000/2500) Black
Specs & where to buy

NETGEAR GS524-300EUS network switch Unmanaged Gigabit Ethernet
(10/100/1000) Grey
Specs & where to buy

NETGEAR MS305E Unmanaged 2.5G Ethernet
(100/1000/2500) Black
Specs & where to buy

NETGEAR GS308E Managed L2/L3 Gigabit Ethernet
(10/100/1000) Black
Specs & where to buy