LG S12EQ.NSJ/S12EQ.UA3 air conditioner Split system White
- Type: Split system
- Product colour: White
- Air conditioner functions: Cooling, Heating
- Inverter technology
- Seasonal efficiency rating (heating) (SCOP): 4
- Certification: ECC
All 73 specificationsProduct page at lgairconditioning.co.uk ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
LG air conditioning and heat pump products are packed with unique features to benefit the user as well as being highly energy efficient. All of LG’s condensers have the Gold-fin coating protecting the surface of the heat exchanger from unnecessary corrosion and extending the life of the unit. The single split wall mount units are Wi-Fi ready. The confidence LG has in its products is reflected in the companies warranty package.
The new line-up offers external units from 4.1kw up to 18.7kw and internal units that include its Artcool Mirror, Deluxe, Standard and Standard Plus wall units, as well as the 4-way Ceiling Cassette, Ceiling Suspended unit and Ceiling Concealed duct units.
Documents
- BrochureProduct Brochure ↗
- BrochureProduct Brochure ↗
- Product information sheetEU Product Fiche ↗
Specifications
Key specifications
- TypeCharacteristics of the device.
- Split system
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 4
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- ECC
- Remote control includedComponent of an electronics device, most commonly a television set, DVD player and home theater systems originally used for operating the device wirelessly from a short line-of-sight distance.
- Yes
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Warranty cardIndicates whether a physical warranty card is included with the product.
- Yes
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 50 dB
Show all 73 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Split system
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Comfort sleeping modeIndicates whether the device features a specialized setting that adjusts temperature and fan speed for improved comfort and reduced noise during sleep.
- Yes
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 6.6
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 3.24
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 3.81
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 3500 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 890 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 4040 W
- Heating capacity in watts (nominal) (Warmer heating season)The nominal amount of heat energy the unit can provide during the warmer period of the heating season, measured in watts.
- 4000 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 890 W
- Heating capacity in watts (nominal) (Colder heating season)The amount of thermal energy the unit can provide for heating during a colder season, measured in watts.
- 5100 W
- Cooling capacity (min)The minimum amount of heat the unit can remove from an indoor space, typically measured in BTU/h or kilowatts.
- 12000 BTU/h
- Cooling capacity (max)Maximum cooling capacity of the air conditioner.
- 12000 BTU/h
- Heating capacity (min)The minimum amount of heat the unit can produce to warm a space, measured in BTU/h.
- 12000 BTU/h
- Heating capacity (max)The maximum amount of heat the unit can generate to warm a space, measured in BTU/h.
- 12000 BTU/h
- TimerA feature that measures a time interval and signals its end.
- Yes
- Timer duration (maximum)The longest period of time that can be set for the countdown or interval timer, measured in h.
- 24 h
- Hose length (min)The minimum required length of the connecting piping between the indoor and outdoor units, measured in m.
- 3 m
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 15 m
- Gas hose diameterThe internal width of the gas connection, typically measured in millimetres.
- 9.52 mm
- Drain hose diameterThe internal diameter of the tube used to remove condensate water from the unit, measured in mm.
- 2.15 cm
- Liquid hose diameterThe internal diameter of the line used for the liquid refrigerant, typically measured in millimetres or inches.
- 6.35 mm
- Dehumidifying capacityThe volume of moisture the device can remove from the air per hour, measured in l/h.
- 1.3 l/h
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- -10 - 48 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- -10 - 48 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R32
Other features
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 4
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- ECC
Packaging content
- Remote control includedComponent of an electronics device, most commonly a television set, DVD player and home theater systems originally used for operating the device wirelessly from a short line-of-sight distance.
- Yes
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Warranty cardIndicates whether a physical warranty card is included with the product.
- Yes
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 50 dB
- Outdoor unit sound power levelThe total acoustic energy emitted by the external component of the system, measured in decibels (e.g. 55 dB).
- 65 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 1620 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 1620 m³/h
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 71.7 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 23 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 48.3 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 25.1 kg
Indoor unit
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Wall-mountable
- Indoor unit noise level (low speed)The sound pressure level emitted by the indoor unit when operating at the lowest fan speed, measured in decibels (dB).
- 27 dB
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 41 dB
- Indoor unit sound power levelThe total acoustic energy emitted by the internal component, measured in decibels (dB).
- 35 dB
- Cooling airflow (indoor unit)The volume of air circulated by the indoor unit during cooling mode, measured in cubic meters per hour (m³/h).
- 2700 m³/h
- Heating airflow (indoor unit)The volume of air delivered by the indoor unit during heating mode, typically measured in cubic meters per hour (m³/h).
- 2700 m³/h
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 1
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 83.7 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 18.9 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 30.8 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 8.7 kg
Power
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
- Hourly energy consumption (cooling)The amount of energy the device uses per hour when used for cooling.
- 3.5 kWh
- Hourly energy consumption (heating)The amount of energy the device uses per hour when used for heating.
- 2.5 kWh
- Annual energy consumption (cooling)This is a measure of the energy used in a year by the air conditioning (AC) when it is used to cool air.
- 186 kWh
- Annual energy consumption (heating) (Average heating season)The estimated amount of electrical energy used for heating during a standard heating season, measured in kilowatt-hours.
- 875 kWh
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 1080 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 1050 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 220 - 240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 15 A
- Design load (cooling)The maximum cooling capacity the unit is designed to provide under standard operating conditions, measured in kW.
- 3.5 kW
- Design load (heating) (Warmer heating season)The thermal output the unit provides during the heating cycle under warmer seasonal conditions, measured in kW.
- 2.5 kW
- Design load (heating) (Average heating season)The average amount of thermal energy required to maintain the desired indoor temperature during the heating season, measured in kilowatts.
- 2.5 kW
- Design load (heating) (Colder heating season)The thermal output the unit is designed to provide during the coldest part of the heating season, measured in kW.
- 2.5 kW
Performance
- Thermostat rangeThe minimum and maximum temperature limits that can be set or maintained by the device, measured in °C.
- -10 - 48 °C
- Air filterIndicates whether the unit is equipped with a filter to remove particles and impurities from the air.
- Yes
- Remotely operatedThe device can be controlled by remote control, which is a device that controls an apparatus by means of radio or infrared signals.
- Yes
Ergonomics
- Cord lengthThe distance from one end of the cord (cable) to the other.
- 3 m
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

LG S3-W18KL3BA air conditioner Split system White

LG CONFORT09C Split system White

LG S3-M18KLRZA air conditioner Split system Silver

LG S09EQ.UA3 air conditioner Air conditioner outdoor unit White

LG S3-M12JARZA air conditioner Split system Silver