LG P24RK air conditioner Air conditioner indoor unit White
- Type: Air conditioner indoor unit
- Product colour: White
- Air conditioner functions: Cooling, Dehumidifying, Heating
- Indoor unit type: Wall-mountable
- Indoor unit noise level (high speed): 56 dB
- Indoor units quantity: 1
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- TypeCharacteristics of the device.
- Air conditioner indoor unit
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Wall-mountable
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 56 dB
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 1
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 120.9 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 23.7 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 34.6 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 18 kg
Show all 34 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Air conditioner indoor unit
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 5.9
- Seasonal efficiency rating (heating) (SCOP) (Average heating season)The ratio of the total heat energy delivered by the device to the total electrical energy consumed during an entire heating season, based on average climate conditions.
- 3.5
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 3.21
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 3.62
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 7030 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 900 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 8650 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 8440 W
- Heating capacity in watts (min)The minimum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 900 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 11400 W
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 30 m
- Dehumidifying capacityThe volume of moisture the device can remove from the air per hour, measured in l/h.
- 2.8 l/h
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- -10 - 48 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- -15 - 24 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Built-in displayA display which is part of the product, so you do not need to attach another display.
- No
Indoor unit
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Wall-mountable
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 56 dB
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 1
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 120.9 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 23.7 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 34.6 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 18 kg
Power
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A+
- Annual energy consumption (cooling)This is a measure of the energy used in a year by the air conditioning (AC) when it is used to cool air.
- 417 kWh
- Annual energy consumption (heating) (Average heating season)The estimated amount of electrical energy used for heating during a standard heating season, measured in kilowatt-hours.
- 3360 kWh
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 2190 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 2330 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 220-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 25 A
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

LG P24RK.SSD air conditioner Split system White
Specs & where to buy

LG P24EL.NS2 air conditioner Air conditioner indoor unit Silver
Specs & where to buy

LG P18RK.SSC air conditioner Split system White
Specs & where to buy

LG A18RL.UUE air conditioner Air conditioner outdoor unit Silver
Specs & where to buy

LG P12RK.UA3 air conditioner Air conditioner outdoor unit White
Specs & where to buy

LG A18RL.NSC air conditioner Air conditioner indoor unit Mirror
Specs & where to buy