LG A18AHM air conditioner Split system Multicolour
- Type: Split system
- Product colour: Multicolour
- Air conditioner functions: Cooling, Dehumidifying, Heating
- Outdoor unit noise level: 53 dB
- Cooling airflow (outdoor unit): 2520 m³/h
- Heating airflow (outdoor unit): 2520 m³/h
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- TypeCharacteristics of the device.
- Split system
- Product colourThe colour e.g. red, blue, green, black, white.
- Multicolour
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 53 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2520 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2520 m³/h
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 87 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 32 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 65.5 cm
Show all 40 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Split system
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Dehumidifying, Heating
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 2.58
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 3
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 5300 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 5440 W
- Cooling capacity (max)Maximum cooling capacity of the air conditioner.
- 18000 BTU/h
- Heating capacity (max)The maximum amount of heat the unit can generate to warm a space, measured in BTU/h.
- 18500 BTU/h
- TimerA feature that measures a time interval and signals its end.
- Yes
- Timer duration (maximum)The longest period of time that can be set for the countdown or interval timer, measured in h.
- 24 h
- Compressor typeThe technology used by the pump to compress the refrigerant and circulate it through the system (e.g. Inverter, Linear, or Rotary).
- Rotary
- Dehumidifying capacityThe volume of moisture the device can remove from the air per hour, measured in l/h.
- 1.8 l/h
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- 18 - 30 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- 16 - 30 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- Multicolour
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R410A
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 53 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2520 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2520 m³/h
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 87 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 32 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 65.5 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 60 kg
Indoor unit
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Wall-mountable
- Indoor unit noise level (high speed)The sound pressure level emitted by the indoor unit when operating at its maximum fan speed, measured in decibels (dB).
- 46 dB
- Cooling airflow (indoor unit)The volume of air circulated by the indoor unit during cooling mode, measured in cubic meters per hour (m³/h).
- 720 m³/h
- Heating airflow (indoor unit)The volume of air delivered by the indoor unit during heating mode, typically measured in cubic meters per hour (m³/h).
- 720 m³/h
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 1
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 92.8 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 14.7 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 52.2 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 15 kg
Power
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 1757 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 1800 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 220-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 8.2 A
Performance
- Climate classEvery fridge freezer has a climate class. This is designation according to the range of room temperatures (usually measured in degrees Celsius) the freezer is designed to work within. Climate classes are set by an international standard and designated according to range from 10°C to 43°C to cover hotter and colder countries.
- T
- Remotely operatedThe device can be controlled by remote control, which is a device that controls an apparatus by means of radio or infrared signals.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

LG A09RK.NSB air conditioner Air conditioner indoor unit Black
Specs & where to buy

LG A12AWH air conditioner Split system Silver, White
Specs & where to buy

LG ARTMIRR18.SET air conditioner Split system Grey, White
Specs & where to buy

LG M18AH air conditioner Air conditioner outdoor unit White
Specs & where to buy

LG NEWSILVER18.SET air conditioner Split system White
Specs & where to buy

LG M30AH air conditioner Air conditioner outdoor unit White
Specs & where to buy