Legrand Keor COMPACT ASI 10 KVA-0 uninterruptible power supply (UPS) Double-conversion (Online) 9000 W 1 AC outlet(s)
- Form factor: Tower
- Product colour: Black, White
- UPS topology: Double-conversion (Online)
- Output power capacity: 10 kVA
- Output power: 9000 W
- Certification: IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
KEOR COMPACT
Keor Compact UPS is a three-phase uninterruptible power supply On-line Double Conversion. It delivers a rated power of 10-15-20 kVA.With its compactness and easy installation and use, Keor Compact is perfect for all typical three phase small power applications, special for small technical room.
Documents
- ManualUser manual ↗
- ManualUser manual ↗
- ManualUser manual ↗
- BrochureProduct Brochure ↗
- BrochureProduct Brochure ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, White
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 20 - 95%
Show all 67 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, White
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 10 kVA
- Output powerThe power that the device can produce.
- 9000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 320 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 480 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output frequency regulationThe range or precision within which the output frequency can be adjusted or maintained, measured in Hz.
- -3 - 3 Hz
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- -1 - 1%
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93.5%
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 98%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Potential-free outputIndicates whether the device provides a dry contact output that is electrically isolated from the internal power circuitry.
- Yes
- Auto shut-offIndicates whether the device automatically powers down after a period of inactivity to save energy.
- Yes
- Detachable power cordIndicates whether the power cable can be removed from the soundbar for easier transport or replacement.
- Yes
Technical details
- Pallet net heightThe vertical measurement of the protective netting used to secure items, measured in millimetres or centimetres.
- 104 cm
- Pallet net lengthThe total length of the protective netting used to secure items on a transport pallet, measured in millimetres or centimetres.
- 94 cm
- Pallet net widthThe horizontal measurement of the protective netting used to secure items on a pallet, expressed in millimetres or centimetres.
- 41 cm
- Pallet net weightThe total weight of the product on a pallet, excluding the weight of the pallet itself, measured in g.
- 91.3 kg
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 260 mm
- DepthThe distance from the front to the back of something.
- 850 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 890 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 74 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 70 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 20 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 1 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 17.4 A
- Power source typeWhat the power source is.
- AC
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 52 dB
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- Network management,Simple Network Management Protocol (SNMP)
Logistics data
- Products per palletQuantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet.
- 1 pc(s)
- Master (outer) case widthThe width of the outer shipping container used for bulk transport, measured in mm.
- 350 mm
- Master (outer) case lengthThe total length of the external shipping container used for bulk transport, measured in millimetres or centimetres.
- 940 mm
- Master (outer) case heightThe vertical measurement of the external shipping container used for bulk transport, typically expressed in millimetres or centimetres.
- 1040 mm
- Master (outer) case gross weightThe total weight of the outer shipping container, including all contained products and packaging materials, measured in kilograms or grams.
- 91.3 kg
- Products per master (outer) caseThe total quantity of individual units contained within a single master shipping case, measured in pc(s).
- 1 pc(s)
Packaging data
- Package weightWeight of the packaged product.
- 86.7 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Legrand Keor COMPACT ASI 10 KVA-1 uninterruptible power supply (UPS) Double-conversion (Online)
9000 W 1 AC outlet(s)

Legrand Keor ASI SPE rack 2U 2.2KVA uninterruptible power supply (UPS) Line-Interactive
1980 W 9 AC outlet(s)

Legrand Keor COMPACT ASI 15 KVA-0 uninterruptible power supply (UPS) Double-conversion (Online)
13500 W 1 AC outlet(s)

Legrand Keor ASI SPE rack 2U 1KVA uninterruptible power supply (UPS) Line-Interactive
800 W 8 AC outlet(s)

Legrand Keor COMPACT ASI 15 KVA-1 uninterruptible power supply (UPS) Double-conversion (Online)
13500 W 1 AC outlet(s)

Legrand Keor ASI SPE rack 2U 1.5KVA uninterruptible power supply (UPS) Line-Interactive
1200 W 8 AC outlet(s)