
Hisense 2MA912TG1 air conditioner Split system White
- Type: Split system
- Multi-split
- Product colour: White
- Air conditioner functions: Cooling, Heating
- Inverter technology
- Seasonal efficiency rating (heating) (SCOP): 4.1
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- TypeCharacteristics of the device.
- Split system
- Multi-splitIndicates whether the system can be connected to multiple units.
- Yes
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 4.1
- Remote control includedComponent of an electronics device, most commonly a television set, DVD player and home theater systems originally used for operating the device wirelessly from a short line-of-sight distance.
- Yes
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 55 dB
- Outdoor unit sound power levelThe total acoustic energy emitted by the external component of the system, measured in decibels (e.g. 55 dB).
- 64 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2800 m³/h
Show all 47 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Split system
- Multi-splitIndicates whether the system can be connected to multiple units.
- Yes
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 7.21
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 3.77
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 4.2
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 5200 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 1800 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 6600 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 5500 W
- Heating capacity in watts (min)The minimum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 1400 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 7200 W
- Refrigerating medium weightThe total mass of the coolant gas used in the cooling system, measured in grams or kilograms.
- 1.07 kg
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 15 m
- Gas hose diameterThe internal width of the gas connection, typically measured in millimetres.
- 9.52 mm
- Liquid hose diameterThe internal diameter of the line used for the liquid refrigerant, typically measured in millimetres or inches.
- 6.35 mm
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- -15 - 48 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- -15 - 24 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Inverter technologyAn “inverter” is a power conversion circuit that electronically regulates the voltage, current and frequency of products such as air conditioners.
- Yes
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R32
Other features
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 4.1
Packaging content
- Remote control includedComponent of an electronics device, most commonly a television set, DVD player and home theater systems originally used for operating the device wirelessly from a short line-of-sight distance.
- Yes
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 55 dB
- Outdoor unit sound power levelThe total acoustic energy emitted by the external component of the system, measured in decibels (e.g. 55 dB).
- 64 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 2800 m³/h
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 81 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 28 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 58 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 37 kg
Indoor unit
- Indoor unit typeThe physical design and mounting style of the internal component of the air conditioning system, such as wall-mountable or cassette.
- Wall-mountable
- Indoor unit noise level (low speed)The sound pressure level emitted by the indoor unit when operating at the lowest fan speed, measured in decibels (dB).
- 19 dB
- Cooling airflow (indoor unit)The volume of air circulated by the indoor unit during cooling mode, measured in cubic meters per hour (m³/h).
- 600 m³/h
- Indoor units quantityThe total number of internal components or handsets included in the system.
- 2
- Indoor unit widthThe size of an indoor unit, measured from one side to another.
- 91.5 cm
- Indoor unit depthThe measurement of the device from front to back, expressed in millimetres or centimetres.
- 21 cm
- Indoor unit heightThe vertical measurement of the internal component of the system, expressed in millimetres.
- 27.5 cm
- Indoor unit weightThe total mass of the internal component of the system, measured in g.
- 9 kg
Power
- Energy efficiency class (heating) (Warmer heating season)The energy efficiency rating of the air conditioning unit during the heating season in warmer climates, indicated by a scale such as A+++, A++, or A+.
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 220-240 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- CurrentThe amount of electrical current flowing through the device, measured in amperes (A).
- 1 A
- Current (cooling)The amount of electrical current drawn by the unit during the cooling process, measured in amperes (e.g. 4.5 A).
- 6.2 A
- Current (heating)The amount of electrical current consumed by the unit during the heating process, measured in amperes (e.g. 5.2 A).
- 6.4 A
- Design load (cooling)The maximum cooling capacity the unit is designed to provide under standard operating conditions, measured in kW.
- 1.38 kW
- Design load (heating) (Warmer heating season)The thermal output the unit provides during the heating cycle under warmer seasonal conditions, measured in kW.
- 1.43 kW
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Hisense KB35YR1A air conditioner Air conditioner indoor unit White
Specs & where to buy

Hisense CA35YR01G air conditioner Air conditioner indoor unit White
Specs & where to buy

Hisense AH242TD air conditioner Air conditioner indoor unit White
Specs & where to buy

Hisense TQ25XE0BG air conditioner Air conditioner indoor unit White
Specs & where to buy

Hisense MINISPLIT INVERTER AT122CB 1TONELADA 220V FRIO - Air conditioner indoor unit White
Specs & where to buy

Hisense TQ35XE0BG air conditioner Air conditioner indoor unit White
Specs & where to buy