Fujitsu AUY 71 UIA-LV Air conditioner outdoor unit White
- Type: Air conditioner outdoor unit
- Product colour: White
- Air conditioner functions: Cooling, Fan, Heating
- Seasonal efficiency rating (heating) (SCOP): 3.9
- Outdoor unit noise level: 52 dB
- Cooling airflow (outdoor unit): 930 m³/h
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Fan, Heating
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 3.9
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 52 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 930 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2470 m³/h
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 79.9 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 29 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 63.2 cm
Show all 29 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Fan, Heating
- IonizerA device that uses high voltage to ionise (electrically charge) air molecules. Air ionisers are used in air purifiers. Airborne particles are attracted to the electrode in an effect similar to static electricity. These ions are de-ionised by seeking earthed conductors, such as walls and ceilings.
- No
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 5.6
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 6800 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 8000 W
- Hose length (min)The minimum required length of the connecting piping between the indoor and outdoor units, measured in m.
- 20 m
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 30 m
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
Other features
- Seasonal efficiency rating (heating) (SCOP)The Seasonal Coefficient of Performance (SCOP) value in heating measures annual energy consumption and efficiency in typical day-to-day use. In the longer term, it takes into account temperature fluctuations and standby periods to give a clear and reliable indication of the typical energy efficiency over an entire heating season.
- 3.9
Outdoor unit
- Outdoor unit noise levelThe sound pressure level emitted by the external compressor unit, measured in decibels (dB).
- 52 dB
- Cooling airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the cooling cycle, measured in cubic meters per hour (m³/h).
- 930 m³/h
- Heating airflow (outdoor unit)The volume of air moved by the outdoor unit fan during the heating cycle, typically measured in cubic meters per hour.
- 2470 m³/h
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 79.9 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 29 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 63.2 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 44 kg
Power
- Energy efficiency class (heating) (Warmer heating season)The energy efficiency rating of the air conditioning unit during the heating season in warmer climates, indicated by a scale such as A+++, A++, or A+.
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
- Power consumption (cooling) (min)The minimum amount of electrical power required to operate the unit in cooling mode, measured in Watts.
- 900 W
- Power consumption (cooling) (max)The maximum amount of electrical energy used by the unit during the cooling process, measured in watts.
- 8000 W
- Power consumption (heating) (min)The minimum amount of electrical power required by the unit to operate in heating mode, measured in Watts.
- 900 W
- Power consumption (heating) (max)The maximum amount of electrical power required by the unit during the heating process, measured in watts (W) or kilowatts (kW).
- 9100 W
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Current (cooling)The amount of electrical current drawn by the unit during the cooling process, measured in amperes (e.g. 4.5 A).
- 12 A
- Current (heating)The amount of electrical current consumed by the unit during the heating process, measured in amperes (e.g. 5.2 A).
- 13.5 A
- Design load (cooling)The maximum cooling capacity the unit is designed to provide under standard operating conditions, measured in kW.
- 2.21 kW
- Design load (heating) (Average heating season)The average amount of thermal energy required to maintain the desired indoor temperature during the heating season, measured in kilowatts.
- 2.26 kW
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Fujitsu ACY 71 UIA-LM Split system Grey, White
Specs & where to buy

Fujitsu AOYG14KMTA Air conditioner outdoor unit White
Specs & where to buy

Fujitsu ACY 71 UiA Split system Grey, White
Specs & where to buy

Fujitsu ASYG14KMTA Air conditioner indoor unit White
Specs & where to buy

Fujitsu AOY 50 Ui-MI2 Air conditioner outdoor unit White
Specs & where to buy

Fujitsu ASY40UI-KM Split system White
Specs & where to buy