Specifications
Key specifications
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 90 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 33 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 83 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 61 kg
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
Show all 38 specificationsShow key specifications only
Features
- TypeCharacteristics of the device.
- Air conditioner outdoor unit
- Air conditioner functionsThe modes of the air conditioner e.g. heating, cooling.
- Cooling, Heating
- Seasonal efficiency rating (cooling) (SEER)The Seasonal Energy Efficiency Ratio (SEER) is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is often measured as a ratio of British thermal units (BTU) to watt-hours.
- 6.1
- Seasonal efficiency rating (heating) (SCOP) (Average heating season)The ratio of the total heat energy delivered by the device to the total electrical energy consumed during an entire heating season, based on average climate conditions.
- 4.2
- Cooling energy efficiency (EER, W/W)The ratio of the cooling capacity to the electrical power input, measured in watts per watt (W/W).
- 3.21
- Heating energy efficiency (COP, W/W)The ratio of heat energy delivered to the electrical energy consumed by the unit, expressed as watts per watt.
- 3.61
- Cooling capacity in watts (nominal)The amount of heat the unit can remove from a space under nominal operating conditions, measured in watts.
- 8500 W
- Cooling capacity in watts (min)The minimum amount of heat energy the unit can remove from a space, measured in watts.
- 2800 W
- Cooling capacity in watts (max)The maximum amount of heat energy the unit can remove from a space or component, measured in watts.
- 10000 W
- Heating capacity in watts (nominal) (Average heating season)The average amount of thermal energy the unit can provide for heating during a typical heating season, measured in watts.
- 10000 W
- Heating capacity in watts (min)The minimum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 2700 W
- Heating capacity in watts (max)The maximum amount of thermal energy the unit can produce to warm a space, measured in watts.
- 11200 W
- Auto fanIndicates whether the device can automatically adjust the fan speed based on the current operating conditions.
- Yes
- Hose length (max)The maximum permissible length of the connecting tube, measured in metres or millimetres.
- 50 m
- Gas hose diameterThe internal width of the gas connection, typically measured in millimetres.
- 1.59 cm
- Drain hose diameterThe internal diameter of the tube used to remove condensate water from the unit, measured in mm.
- 2.56 cm
- Liquid hose diameterThe internal diameter of the line used for the liquid refrigerant, typically measured in millimetres or inches.
- 9.52 mm
- Dehumidifying capacityThe volume of moisture the device can remove from the air per hour, measured in l/h.
- 2.5 l/h
- Operating temperature (cooling) (T-T)The range of ambient temperatures within which the device can operate effectively, measured in °C.
- -15 - 46 °C
- Operating temperature (heating) (T-T)The range of ambient temperatures, measured in degrees Celsius, within which the unit can effectively operate while in heating mode (e.g. -25°C to +18°C).
- -15 - 24 °C
Design
- Product colourThe colour e.g. red, blue, green, black, white.
- White
- Refrigerating mediumThe type of refrigerant gas used to transfer heat (e.g., R600a or R290).
- R410A
Outdoor unit
- Outdoor units quantityThe total number of external components included in the system.
- 1
- Outdoor unit widthThe measurement of the unit from side to side, expressed in millimetres or centimetres.
- 90 cm
- Outdoor unit depthThe measurement of the product from front to back, expressed in millimetres or centimetres.
- 33 cm
- Outdoor unit heightThe vertical measurement of the external component of the system, expressed in millimetres or centimetres.
- 83 cm
- Outdoor unit weightThe total mass of the external component, measured in g.
- 61 kg
Power
- Energy efficiency class (heating) (Average heating season)The energy efficiency rating of the unit during the heating season, indicated by a scale of letter and plus symbols (e.g. A+++).
- A+
- Energy efficiency class (cooling) (legacy scale)This is a measure of the energy efficiency of the air conditioning (AC) when it is used to cool air. There are energy efficiency classes from A+++ to G, A+++ being the most energy efficient, G the least efficient.
- A++
- Annual energy consumption (cooling)This is a measure of the energy used in a year by the air conditioning (AC) when it is used to cool air.
- 487 kWh
- Annual energy consumption (heating) (Average heating season)The estimated amount of electrical energy used for heating during a standard heating season, measured in kilowatt-hours.
- 2662 kWh
- AC input voltageThe voltage of the AC electricity that is inputted into the product.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Current (cooling)The amount of electrical current drawn by the unit during the cooling process, measured in amperes (e.g. 4.5 A).
- 17 A
- Current (heating)The amount of electrical current consumed by the unit during the heating process, measured in amperes (e.g. 5.2 A).
- 17 A
- Design load (cooling)The maximum cooling capacity the unit is designed to provide under standard operating conditions, measured in kW.
- 8.5 kW
- Design load (heating) (Colder heating season)The thermal output the unit is designed to provide during the coldest part of the heating season, measured in kW.
- 8 kW
Performance
- Air filterIndicates whether the unit is equipped with a filter to remove particles and impurities from the air.
- Yes
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Fujitsu ARHG24LHTBP air conditioner Air conditioner indoor unit Stainless steel
Specs & where to buy

Fujitsu ARHG30LMLE Air conditioner indoor unit Stainless steel