
FSP FP 400 uninterruptible power supply (UPS) Line-Interactive 0.4 kVA 240 W 2 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.4 kVA
- Output power: 240 W
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The line-interactive FP Series with a compact size can provide stable power protection against surges and spikes. It is ideal for PC users or small business companies, as well as for small telecom applications. Its embedded microprocessor controller guarantees high reliability
It can automatically restart while AC power is recovering. With Simulated sine wave, off-mode charging, and cold start function, it will be a good choice.
Features
- Compact size
- Excellent microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- Generator compatible (Option)
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.4 kVA
- Output powerThe power that the device can produce.
- 240 W
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 4.5 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
Show all 35 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.4 kVA
- Output powerThe power that the device can produce.
- 240 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 162 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 290 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 220 V
- Automatic Voltage Regulation (AVR)Indicates whether the device can automatically stabilize the input voltage to a constant level without switching to battery power.
- Yes
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Audible alarm modesThe specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.
- Battery replacement
- Auto-restartIndicates whether the device automatically reboots itself after a power failure or a system crash.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 110 mm
- DepthThe distance from the front to the back of something.
- 294 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 145 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 3.55 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 4.5 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 6 h
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
- Off-mode chargingIndicates whether the internal battery can be charged while the device is switched off.
- Yes
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overcharge, Overload
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Type F
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 2 AC outlet(s)
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 324 mm
- Package depthThe distance from the front to the back of the packaging.
- 140 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 220 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

FSP FP 600 uninterruptible power supply (UPS) Line-Interactive 0.6 kVA
360 W 2 AC outlet(s)

FSP FP 800 uninterruptible power supply (UPS) Line-Interactive 0.8 kVA
480 W 2 AC outlet(s)

FSP Nano 800 uninterruptible power supply (UPS) Standby (Offline) 0.8 kVA
480 W 2 AC outlet(s)

FSP Knight KN-1101TS uninterruptible power supply (UPS) 1 kVA
800 W 4 AC outlet(s)

FSP FP 1500 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 4 AC outlet(s)

FSP Knight KN-1106RL uninterruptible power supply (UPS) 6 kVA
4800 W 4 AC outlet(s)