FSP Custos CU-1103TL uninterruptible power supply (UPS) 3 kVA 2700 W 7 AC outlet(s)
- Form factor: Tower
- Product colour: Black
- Output power capacity: 3 kVA
- Output power: 2700 W
- Output connections: 1 x IEC 320 C19 & 6 x IEC 320 C13
- Certification: IEC 62040-1 IEC-62040-2 CE
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Ideal for medium-density power protection demand, Custos 9X+ series provides Rack/Tower form factor to fit diverse environment. Despite its compact footprint, this UPS incorporates internal battery packs which can be accessed via the front panel for maintenance checks and replacement without removing the UPS from its rack mounting. The LCD display panel can be easily shifted by pressing buttons to suit the installation format, vertically stand or flatly rack mount. Besides, IT personnel can manage equipment well from learning remaining backup time information via LCD display.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2700 W
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 1 x IEC 320 C19 & 6 x IEC 320 C13
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-1 IEC-62040-2 CE
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Display typeType of display (screen) e.g. LCD.
- LCD
Show all 38 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2700 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 55 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 300 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 110 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output voltage regulationThe maximum percentage by which the output voltage may deviate from the nominal value, measured in %.
- 2%
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 88%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.9
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 5:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2%
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Other features
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 1 x IEC 320 C19 & 6 x IEC 320 C13
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 88 mm
- DepthThe distance from the front to the back of something.
- 600 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 438 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 13.8 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-1 IEC-62040-2 CE
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 20 - 90%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C20 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 7 AC outlet(s)
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 50 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

FSP Knight KN-1102TS uninterruptible power supply (UPS) 2 kVA
1600 W 8 AC outlet(s)

FSP Custos CU-1102TL uninterruptible power supply (UPS) 2 kVA
1800 W 8 AC outlet(s)

FSP Knight KN-1106RL uninterruptible power supply (UPS) 6 kVA
4800 W 4 AC outlet(s)

FSP IndusPower IN-3360TL uninterruptible power supply (UPS) 60 kVA
48000 W

FSP Knight KN-1101TS uninterruptible power supply (UPS) 1 kVA
800 W 4 AC outlet(s)

FSP CU-1110TL uninterruptible power supply (UPS) 10 kVA
9000 W