Eaton T982C2-F-SL-015 power distribution unit (PDU) 12 AC outlet(s) 1U
- AC outlets quantity: 12 AC outlet(s)
- Nominal input voltage: 110-125 V
- AC input frequency: 50 - 60 Hz
- Maximum input current per phase: 24 A
- Cable length: 4.57 m
- Power plug: NEMA L5-30P
All 15 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Designed for reliable and cost effective power distribution, Basic ePDUs have the form factor and receptacle choices to meet the needs of the demanding data center architect. With power levels ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 12 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L5-30P
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–20R
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 482.6 mm
- DepthThe distance from the front to the back of something.
- 177.8 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 43.2 mm
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 110-125 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 24 A
Features
- Cable lengthHow long the cable is.
- 4.57 m
- Rack capacityThe spase that device fill in rack.
- 1U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Basic
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 609.6 mm
- Package depthThe distance from the front to the back of the packaging.
- 254 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 101.6 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton PW107MI0UC65 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specs & where to buy

Eaton TPC2105-2-108 power distribution unit (PDU) 10 AC outlet(s) 1U Black
Specs & where to buy

Eaton T8S-3189 power distribution unit (PDU) 8 AC outlet(s) 1U Black
Specs & where to buy

Eaton TPC115-3245 power distribution unit (PDU) 10 AC outlet(s) 1U
Specs & where to buy

Eaton TPC115-10-3775 power distribution unit (PDU) 10 AC outlet(s) 1U Grey
Specs & where to buy

Eaton T2235-3209 power distribution unit (PDU) 9 AC outlet(s) 1U Black
Specs & where to buy