Eaton Power Xpert 9395P uninterruptible power supply (UPS) Double-conversion (Online) 900 kVA 900000 W
- Form factor: Tower
- Product colour: Black
- UPS topology: Double-conversion (Online)
- Output power capacity: 900 kVA
- Output power: 900000 W
- Communication options, slot: 4
All 40 specificationsProduct page at eaton.com ↗
Versions
825000 W · 0.92 · 83 dB · 2373 kg
825000 W · 0.92 · 83 dB · 2378 kg
825000 W · 0.92 · 83 dB · 2408 kg
825000 W · 0.92 · 83 dB · 2414 kg
825000 W · 0.92 · 83 dB · 2558 kg
825000 W · 0.92 · 83 dB · 2593 kg
825000 W · 0.92 · 85 dB · 2.42 kg
825000 W · 0.92 · 85 dB · 2388 kg
825000 W · 0.92 · 85 dB · 2423 kg
900000 W · 0.92 · 83 dB · 2413 kg
900000 W · 0.92 · 83 dB · 2593 kg
900000 W · 1 · 83 dB · 2373 kg
900000 W · 1 · 83 dB · 2378 kg
900000 W · 1 · 83 dB · 2408 kg
900000 W · 1 · 83 dB · 2413 kg
900000 W · 1 · 83 dB · 2414 kg
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Double conversion UPS
10% more power
- 96.3% double conversion efficiency, delivers 10% more power than the previous 9395 UPS.
- Complete isolation of output power from all input power anomalies, to deliver 100% conditioned, perfect sine-wave output – even during severe power disturbance.
- High efficiency even when UPS load levels are low, optimised by Variable Module Management System (VMMS).
- Energy Saver System (ESS) improves efficiency levels to 99% by suspending power modules when double conversion is not required. Switches to double conversion mode in less than 2 milliseconds in event of pre-set input limits being exceeded. Filtering against fast low-energy transients provided by ESS.
- Producing 18% less heat helps reduce the need for cooling. Designed for continuous operation at ambient temperatures up to 40°C without de-rating. Can also deliver safe power in higher temperatures without shutting down.
Ultimate resiliency
- HotSync patented load-sharing technology enables parallel operating of static converters without communication or load- share signals. Eliminating the communication link eliminates risk of single point of failure.
- One static switch per UPS enables the full bypass capacity to be achieved from day one. Power modules can be added as loads increase.
- Wide power factor range meets rapidly changing load power factor without de-rating.
- Intelligent battery charging through Advanced Battery Management prevents unnecessary charging and significantly retards battery wear rate.
Scalability and flexibility
- Number of power modules per UPS can be specified.
- Layout can be chosen to suit installation: back-to-back, L-shaped etc. Front-accessible design minimises installation costs and saves valuable data centre space.
- Preferred bypass topology can be specified. Additional modules can be added as power load increases.
- Centralised multi-module paralleled 9395P systems are supported by the Eaton System Bypass Module (SBM). Available in ratings from 2000 A to 5000 A as standard, the SBM includes a continuous-duty centralised static switch, backfeed protection device and centralised bypass systems.
- Service disconnect in each power module allows easy maintenance while the UPS is supporting the load in double conversion mode.
- More than 90% of materials used can be recycled, decreasing end-of-life impact.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 900 kVA
- Output powerThe power that the device can produce.
- 900000 W
- Communication options, slotSpecifies the communications option slot.
- 4
- Output connection typeThe type of connection used for outputs from this device e.g. USB.
- Fixed
- Electrical input connectionThe type of connector or terminal used to provide electrical power to the device (e.g. IEC C14).
- Fixed
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE Marked RoHS Compliant CB
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Show all 40 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- ModularIndicates whether the unit features a modular design that allows for the expansion or replacement of individual components.
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 900 kVA
- Output powerThe power that the device can produce.
- 900000 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 380 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 415 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 96%
- Efficiency (On-line mode)The ratio of output power to input power when the device is operating in on-line mode, measured in %.
- 99%
- Efficiency (ECO mode)The energy efficiency of the device when operating in its power-saving ECO mode, measured in %.
- 99%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.99
- Output power factorThe ratio of the real power delivered to the load to the apparent power supplied by the device.
- 0.92
- Potential-free outputIndicates whether the device provides a dry contact output that is electrically isolated from the internal power circuitry.
- Yes
- Soft startIndicates whether the device gradually increases power upon activation to prevent electrical surges and mechanical stress.
- Yes
- Auto shut-offIndicates whether the device automatically powers down after a period of inactivity to save energy.
- Yes
Other features
- Communication options, slotSpecifies the communications option slot.
- 4
- Output connection typeThe type of connection used for outputs from this device e.g. USB.
- Fixed
- Electrical input connectionThe type of connector or terminal used to provide electrical power to the device (e.g. IEC C14).
- Fixed
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 3800 mm
- DepthThe distance from the front to the back of something.
- 880 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1880 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 2593 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE Marked RoHS Compliant CB
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Battery
- Battery voltageThe voltage (V) of the battery.
- 480 V
- Number of battery cellsThe total quantity of individual battery cells used to power the device, including configurations with primary and backup cells (e.g., 1+2).
- 240
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 0 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 0 min
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- No
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 360 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 83 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 93PM UPS uninterruptible power supply (UPS) Double-conversion (Online) 50 kVA
50000 W
Specs & where to buy

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online) 200 kVA
200000 W
Specs & where to buy

Eaton Power Xpert 9395P uninterruptible power supply (UPS) Double-conversion (Online) 600 kVA
550000 W
Specs & where to buy

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online) 250 kVA
250000 W
Specs & where to buy

Eaton Power Xpert 9395P uninterruptible power supply (UPS) Double-conversion (Online) 300 kVA
275000 W
Specs & where to buy

Eaton 93PM uninterruptible power supply (UPS) Double-conversion (Online) 300 kVA
95000 W
Specs & where to buy