Eaton FAZ-C63/1 circuit breaker Miniature circuit breaker Type C 1 module(s)
- Circuit breaker type: Miniature circuit breaker
- Type: Type C
- Rated current: 63 A
- Doesn't contain: Lead, Mercury, Cadmium
- Compliance certificates: UL, RoHS, UKCA, WEEE
- DIN rail mounting
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Eaton Moeller series xEffect - FAZ MCB. FAZ, 1-pole, tripping characteristic: C, rated current In: 25 A.
Documents
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Circuit breaker typeThe specific design and functional category of the protection device, such as a Miniature circuit breaker or a Residual-current device.
- Miniature circuit breaker
- TypeCharacteristics of the device.
- Type C
- Rated currentThe maximum amount of electric current the device is designed to carry continuously under specified conditions, measured in amperes.
- 63 A
- Doesn't containSpecifies the harmful or restricted substances that are not present in the product (e.g. Acetone, Alcohol, or Aluminium).
- Lead, Mercury, Cadmium
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, RoHS, UKCA, WEEE
- DIN rail mountingIndicates whether the device can be installed on a standard DIN rail for secure mounting in a control cabinet or electrical enclosure.
- Yes
- Number of modular spacingsThe total number of standard module widths (typically 18 mm) occupied by the device on a DIN rail.
- 1
- Mounting depthThe distance between where the back of the device is mounted to (usually the wall) and the front of the device.
- 7.05 cm
- Release characteristicDefines the current threshold at which the device will trip to protect against overcurrent or short-circuit conditions (e.g., B, C, or D).
- C
- Connectable solid conductor cross-sectionThe maximum and minimum cross-sectional area of a solid wire that can be securely connected to the terminals, typically measured in square millimetres (mm²).
- 1 - 25 mm²
Show all 38 specificationsShow key specifications only
Features
- Circuit breaker typeThe specific design and functional category of the protection device, such as a Miniature circuit breaker or a Residual-current device.
- Miniature circuit breaker
- TypeCharacteristics of the device.
- Type C
- Breaking capacityThe maximum fault current that the device can safely interrupt without sustaining permanent damage, measured in A.
- 5000 A
- Number of polesThe number of electrical poles or phases the device is designed to connect or switch (e.g., 1P, 3P).
- 1
- Modules quantity (max)The maximum number of modules that can be installed or accommodated, measured in module(s).
- 1 module(s)
- Pollution degreeThe level of contamination of the environment in which the device is used, categorized by the risk of electrical breakdown due to pollution (e.g. 2 or 3).
- 2
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50 - 60 Hz
Power
- Rated currentThe maximum amount of electric current the device is designed to carry continuously under specified conditions, measured in amperes.
- 63 A
- Input voltageThe voltage (V) which is required to power the product.
- 240 - 415 V
- Rated voltageThe specified electrical potential difference at which the device is designed to operate, measured in volts.
- 254 V
- Power dissipationThe amount of electrical power lost as heat during operation, typically measured in watts (W).
- 5.2 W
- Total power lossThe amount of electrical energy dissipated as heat during operation, measured in W.
- 5.5 W
Sustainability
- Doesn't containSpecifies the harmful or restricted substances that are not present in the product (e.g. Acetone, Alcohol, or Aluminium).
- Lead, Mercury, Cadmium
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- UL, RoHS, UKCA, WEEE
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 60947-2 IEC/EN 60898 EN45545-2 IEC 61373
Design
- DIN rail mountingIndicates whether the device can be installed on a standard DIN rail for secure mounting in a control cabinet or electrical enclosure.
- Yes
- Overvoltage categoryThe classification of the transient overvoltage environment in which the device can be safely operated (e.g. CAT III).
- CAT III
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20, IP40
- Product colourThe colour e.g. red, blue, green, black, white.
- White
Technical details
- Number of modular spacingsThe total number of standard module widths (typically 18 mm) occupied by the device on a DIN rail.
- 1
- Release characteristicDefines the current threshold at which the device will trip to protect against overcurrent or short-circuit conditions (e.g., B, C, or D).
- C
- Connectable solid conductor cross-sectionThe maximum and minimum cross-sectional area of a solid wire that can be securely connected to the terminals, typically measured in square millimetres (mm²).
- 1 - 25 mm²
- Connectable stranded conductor cross-sectionThe maximum and minimum cross-sectional area of flexible, stranded wires that can be securely connected to the terminals, typically measured in square millimetres (mm²).
- 1 - 25 mm²
- Rated insulation voltage (Ui)The maximum voltage that the insulation of the device can withstand without failure under specified conditions.
- 440 V
- Rated short-circuit breaking capacity (Icn, EN 60898, 230V)The maximum fault current that the device can safely interrupt without sustaining damage, according to the EN 60898 standard at 230V.
- 10 kA
- Rated short-circuit breaking capacity (Icn, EN 60898, 400V)The maximum fault current that the device can safely interrupt without sustaining permanent damage, measured at 400V according to the EN 60898 standard.
- 10 kA
- Rated short-circuit breaking capacity (Icu, IEC 60947-2, 400V)The maximum fault current that the device is capable of breaking without sustaining damage, according to the IEC 60947-2 standard at 400V.
- 15 kA
- Rated short-circuit breaking capacity (Icu, IEC 60947-2, 230V)The maximum fault current that the device can safely interrupt at 230V according to the IEC 60947-2 standard without sustaining permanent damage.
- 15 kA
- Rated impulse withstand voltage (Uimp)The maximum peak voltage of a transient overvoltage that the device can withstand without failure, measured in kV.
- 4 kV
- Rated switching capacityThe maximum current that the device can safely interrupt under specified conditions without sustaining damage.
- 10 kA
- DC nominal voltageThe standard direct current voltage required for the device to operate correctly, measured in volts.
- 48 V
Weight & dimensions
- Mounting depthThe distance between where the back of the device is mounted to (usually the wall) and the front of the device.
- 7.05 cm
- WidthThe measurement or extent of something from side to side.
- 17.7 mm
- DepthThe distance from the front to the back of something.
- 80 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 75.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 122 g
Packaging content
- Quantity per packThe number of individual units contained within a single sales package, measured in pc(s).
- 1 pc(s)
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -25 - 75 °C
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton FAZ-C25/1 circuit breaker Miniature circuit breaker Type C 1 module(s)
Specs & where to buy

Eaton FAZ-C40/2 circuit breaker Miniature circuit breaker
Specs & where to buy

Eaton PKZM0-0,25-C circuit breaker Motor protective circuit breaker 3
Specs & where to buy

Eaton FAZ-C10/1-NA circuit breaker Miniature circuit breaker Type C
Specs & where to buy

Eaton FAZ-C20/2 circuit breaker Miniature circuit breaker Type C
Specs & where to buy

Eaton FRCMM-16/2/003-G/A circuit breaker Residual-current device
Specs & where to buy