Eaton EMIH02 power distribution unit (PDU) 8 AC outlet(s) 1U Black
- AC outlets quantity: 8 AC outlet(s)
- Cables included: LAN (RJ-45)
- Rack mount kit
- Operating temperature (T-T): 0 - 60 °C
- Compliance certificates: RoHS
- Nominal input voltage: 230 V
All 37 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Button mounting on rear and sides, variable mounting bracket. 1U/2U form factor ePDUs can be mounted horizontaly, vertically, or under a surface.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- LAN (RJ-45)
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 10 A
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 10 A
Show all 37 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 8 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C14 coupler
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- LAN (RJ-45)
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 44.5 mm
- DepthThe distance from the front to the back of something.
- 482.6 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 203 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 2.6 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CB, CE, EN 60950-1:2006/A11:2009/A1:2010/A12:2011 Safety - Part 1: General Requirements, IEC 60950-1(ed.2), IEC 60950-1(ed.2);am1 EN 55022:2010, EN 61000-6-2:2005 Part 6-2, EN 50581 : 2012, REACH, WEEE, PEP, ISO 9001:2008, ISO 14001:2004
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 10 A
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 10 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 2300 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Input connection typeThe type of connection /port for the input(s) into this device e.g. USB.
- IEC-320-C20
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 8 x C13
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current
- Firmware upgradeableIndicates whether the internal software of the device can be updated to a newer version to improve performance or add features.
- Yes
- Firmware upgradeable viaThe method or interface used to update the internal system software of the device (e.g., via USB, Network, or a Web Interface).
- Network, USB
Network
- Supported network protocolsNetwork protocols tested as compatible with this product e.g. FTP,HTML, POP.
- HTTP, HTTPS, SSL, Telnet, FTP, SNMP, SMTP, DNS, DHCP, LDAP, RADIUS
Performance
- Management protocolsThe communication standards used for the remote administration and monitoring of the device (e.g. LoRaWAN).
- SNMP, Telnet
- Cable colourColour of the cable e.g. white, gray.
- Black
Features
- Cable lengthHow long the cable is.
- 3 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 1U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered
- Form factorThe shape or design of the product.
- Rackmount
- Rack mountingThe type of mounting that can position devices in a shelving system (rack).
- Yes
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Packaging data
- Package weightWeight of the packaged product.
- 3.8 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton EMIH28 power distribution unit (PDU) 8 AC outlet(s) 1U Black
Specs & where to buy

Eaton EILB26 power distribution unit (PDU) 2 AC outlet(s) 0U Black
Specs & where to buy

Eaton TPC2806 power distribution unit (PDU) 7 AC outlet(s) 1U Black
Specs & where to buy

Eaton EILB24 power distribution unit (PDU) 2 AC outlet(s) 0U Black
Specs & where to buy

Eaton EMI136-06 power distribution unit (PDU) 30 AC outlet(s) 0U Black
Specs & where to buy

Eaton EBAH11 power distribution unit (PDU) 6 AC outlet(s) Black
Specs & where to buy