Eaton EMAB16 power distribution unit (PDU) 24 AC outlet(s) 0U Black
- AC outlets quantity: 24 AC outlet(s)
- Operating temperature (T-T): 0 - 60 °C
- Compliance certificates: RoHS
- Nominal input voltage: 230 V
- AC input frequency: 50 Hz
- Maximum current: 32 A
All 16 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Switch and meter outlets & IT equipment across A and B feed: Combines both Switched and Metered Outlet functionality together in 1 ePDU
ePDU G3 Managed models allow complete lights-out control and metering of devices including devices powered across multiple ePDUs. They include IEC Class 1 (±1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A and kWh, and the ability to daisy chain 8 ePDUs to share the same network connection and IP address.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC 60309
- AC outlet typesThe type of outlet for AC electricity.
- BS 1363, C13 coupler, C19 coupler
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 53 mm
- DepthThe distance from the front to the back of something.
- 1604 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 52 mm
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 60 °C
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 32 A
Design
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Switched
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Cable lengthHow long the cable is.
- 3 m
- Rack capacityThe spase that device fill in rack.
- 0U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton EMAB20 power distribution unit (PDU) 24 AC outlet(s) 0U Black

Eaton EMAB05 power distribution unit (PDU) 24 AC outlet(s) 0U Black

Eaton EMAB22 power distribution unit (PDU) 24 AC outlet(s) 0U Black

Eaton EMAB04 power distribution unit (PDU) 24 AC outlet(s) 0U Black

Eaton EMAB33 power distribution unit (PDU) 24 AC outlet(s) 0U Black