Eaton 9SX15KPMAU uninterruptible power supply (UPS) Double-conversion (Online) 15 kVA 15000 W
- Form factor: Rackmount/Tower
- Product colour: Black, Grey
- UPS topology: Double-conversion (Online)
- Output power capacity: 15 kVA
- Output power: 15000 W
- Operating temperature (T-T): 0 - 50 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Eaton 9SX (AP) UPS range provide stable power for Critical IT Infrastructure, Industrial, Manufacturing, and Medical devices. The UPS uses advanced technologies to improve on power and dimensional efficiencies, to help with cost savings in both the electricity and space aspects. This range of UPS incorporates robust designs to enhance durability, making it suitable for a wider range of applications.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 15 kVA
- Output powerThe power that the device can produce.
- 15000 W
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 50 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 4000 m
- Rack capacityThe spase that device fill in rack.
- 3U
Show all 31 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 15 kVA
- Output powerThe power that the device can produce.
- 15000 W
- Rack capacityThe spase that device fill in rack.
- 3U
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 160 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 300 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1/3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 1/3
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.995
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 1%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 438 mm
- DepthThe distance from the front to the back of something.
- 589 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 129 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 23.7 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 50 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 4000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Ports & interfaces
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- USB port typeThe physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).
- USB Type-B
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 9SX (AP) uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
20000 W

Eaton 9SX uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 9 AC outlet(s)

Eaton 9SX (AP) uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
20000 W

Eaton 9SX3000I-HW uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 9 AC outlet(s)

Eaton 9SX (AP) uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
20000 W

Eaton 9SX2000I-HW uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1800 W 8 AC outlet(s)