
Eaton 9PX6KIRTNBPG2 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA 6000 W
- Form factor: Rackmount/Tower
- Product colour: Black, Silver
- UPS topology: Double-conversion (Online)
- Output power capacity: 6 kVA
- Output power: 6000 W
- Nominal output voltage: 230 V
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Eaton 9PX Gen2 UPS HotSwap Netpack, 6000 VA, 6000 W, Input: Hardwired, Outputs: (2) C13, (3) C39, Hardwired, Rack/tower, 3U, Gigabit Network card included, Rack-mounting kit included, Maintenance bypass included
Documents
- BrochureProduct Brochure ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 6000 W
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- Eaton Brlightlayer Software suite
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, UKCA, cULus
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
Show all 44 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- Control typeThe way in which the device is controlled.
- Buttons
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 6 kVA
- Output powerThe power that the device can produce.
- 6000 W
- Rack capacityThe spase that device fill in rack.
- 3U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Pure sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 176 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 276 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 0.965%
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 230 V
Software
- Bundled softwareSoftware distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
- Eaton Brlightlayer Software suite
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 440 mm
- DepthThe distance from the front to the back of something.
- 684 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 130 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 45.1 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- CE, UKCA, cULus
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3, ENERGY STAR certified, CE, cULus, UKCA, Cm, Ukr, RCM
Packaging content
- Rack mount kitIndicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.
- Yes
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- USB cable
- Management card includedIndicates whether a dedicated network management card for remote monitoring and control is included with the unit.
- Yes
Sustainability
- Sustainability certificatesThe environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).
- ENERGY STAR
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 5 Ah
- Battery voltageThe voltage (V) of the battery.
- 12 V
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, Terminal
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.99
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 40 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 9PX11KIRTNBPG2 uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA
11000 W
Specs & where to buy

Eaton 9PX6KIRTNG2 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
6000 W
Specs & where to buy

Eaton 9PX11KIRTNG2 uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA
11000 W
Specs & where to buy

Eaton 9PX8KIRTNG2 uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
8000 W
Specs & where to buy

Eaton 9PX6KP2G2 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA
5400 W
Specs & where to buy

Eaton 9SXEBM240RT3UG2 uninterruptible power supply (UPS) Double-conversion (Online)
Specs & where to buy