Eaton 9PX5K uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA 4500 W 4 AC outlet(s)
- Form factor: Rackmount/Tower
- UPS topology: Double-conversion (Online)
- Output power capacity: 5 kVA
- Output power: 4500 W
- Nominal output voltage: 208 V
- Nominal input voltage: 208 V
All 41 specificationsProduct page at powerquality.eaton.com ↗
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Delivering premium backup power and scalable battery runtimes for servers, voice/data networks and storage systems, the Eaton 9PX UPS is the ideal solution for both rack and stand-alone installations. With a graphical LCD interface and robust power management software, managing a UPS has never been easier — even in virtualized environments.
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 5 kVA
- Output powerThe power that the device can produce.
- 4500 W
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-2:2006 Cat C2 / CISPR22-A / FCC-15 A
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- CE / cULus / NOM
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 60 °C
Show all 41 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 5 kVA
- Output powerThe power that the device can produce.
- 4500 W
- Rack capacityThe spase that device fill in rack.
- 3U
- Cable lengthHow long the cable is.
- 1.83 m
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 176 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 276 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 5%
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 20 A
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 439 mm
- DepthThe distance from the front to the back of something.
- 721 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 130 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 48 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC 62040-2:2006 Cat C2 / CISPR22-A / FCC-15 A
Safety regulation & standards
- SafetyList of regulatory safety standards for all countries in which this product has been certified.
- CE / cULus / NOM
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
- Response timeThe response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
- 0 ms
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 3 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 7 min
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA L6-20R, NEMA L6-30R
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L6-30P
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 4 AC outlet(s)
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.9
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 45 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 9PX11KHW uninterruptible power supply (UPS) 11 kVA
10000 W

Eaton 9PX uninterruptible power supply (UPS) 6 kVA
5400 W

Eaton 9PX11KPM uninterruptible power supply (UPS)

Eaton 9SX8KiPM uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA
7200 W

Eaton 9PX uninterruptible power supply (UPS) 11 kVA
10000 W 10 AC outlet(s)

Eaton 9SX11KiPM uninterruptible power supply (UPS) Double-conversion (Online) 11 kVA
10000 W