Eaton 9PX3000IRTANZ-L uninterruptible power supply (UPS) Line-Interactive 3 kVA 2400 W 10 AC outlet(s)
- Form factor: Rackmount/Tower
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 3 kVA
- Output power: 2400 W
- Operating temperature (T-T): 0 - 40 °C
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The Eaton 9PX lithium-ion rackmount and tower UPS provides 8 to 10 years of life expectancy for UPS and batteries. The 9PX lithium-ion UPS has power ratings ranging from 1 to 3 kVA, with low and high voltage options and offers up to four optional external battery modules for extra runtime. The 9PX lithium-ion UPS, available in rackmount and tower form, has the same reliable features as the lead-acid UPS, including load segments that allow for prioritized shutdown, remote power on (RPO), remote on/off (ROO) and output relay ports that increase control capabilities.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2400 W
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 1500 - 3000 m
Show all 54 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount/Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- Cooling typeThe method used to cool the device or to cool the air around the device.
- Active
- Built-in fanIndicates whether the product has an integrated fan for active cooling.
- Yes
- Control typeThe way in which the device is controlled.
- Buttons
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 3 kVA
- Output powerThe power that the device can produce.
- 2400 W
- Rack capacityThe spase that device fill in rack.
- 2U
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 176 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 276 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 40/70 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 200 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Output frequency regulationThe range or precision within which the output frequency can be adjusted or maintained, measured in Hz.
- 1 Hz
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 296 J
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
- Detachable power cordIndicates whether the power cable can be removed from the soundbar for easier transport or replacement.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 440 mm
- DepthThe distance from the front to the back of something.
- 605 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86.5 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 22.8 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- IEC/EN 62040-1, IEC/EN 62040-2 Cat C1, IEC/EN 62040-3, UL 1778, CSA 22.2, CISPR22 Class B, FCC part 15 Class B, CE, CB, EAC
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 55 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1500 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 1500 - 3000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Lithium-Ion (Li-Ion)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 9 Ah
- Battery voltageThe voltage (V) of the battery.
- 76.8 V
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 8 year(s)
- Charging currentThe amount of electrical current supplied during the charging process, measured in amperes (e.g., 2/6/12).
- 1.7 A
- Hot-swap batteryIndicates whether the battery can be replaced while the unit remains powered on and operational.
- Yes
- Cold startIndicates whether the unit can be started or operated correctly under specific initial conditions, such as very low temperatures or without an external power source.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- C20 coupler
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- USB 2.0 ports quantityNumber of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
- 1
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
- Ethernet LAN (RJ-45) portsNumber of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
- 1
Network
- Cabling technologyType of cable technology performance.
- 10/100Base-T
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Power source typeWhat the power source is.
- AC
Performance
- Power factorThe ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.
- 0.99
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 47 dB
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Eaton 5PX Gen2 uninterruptible power supply (UPS) Line-Interactive 1 kVA
1000 W 8 AC outlet(s)

Eaton 9PX 2000VA ANZ uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA
1800 W 6 AC outlet(s)

Eaton 5PX1000IRT2UG2 uninterruptible power supply (UPS) Line-Interactive 1 kVA
1000 W 8 AC outlet(s)

Eaton 3SM36B uninterruptible power supply (UPS) Standby (Offline)
36 W

Eaton 5PX1500IRT2UG2 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1500 W 8 AC outlet(s)

Eaton 9PX 3000i RT2U Netpack Li-Ion uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2400 W 10 AC outlet(s)